Opens in a new tab
Swimming pool ladder
Pool Care

Pool Heater Flow Error Codes: Diagnosing LO, PS, and CHECK FLOW on Hayward, Pentair, and Jandy

ProTuff Products logo

ProTuff Team
May 6, 2026 · Equipment Troubleshooting

Your pool heater just flashed a code — LO, ERR PS, or CHECK FLOW — and now it won’t fire. Before you call a technician, there’s something every pool owner needs to know.

Ninety percent of all pool heater service calls trace back to a single root cause: not enough water flowing through the heater. That means the fix is almost always outside the heater itself — in your filter, your pump basket, or your pump speed settings. This guide breaks down exactly what each brand’s flow error code means, how to diagnose the real cause in 15 minutes, and when a part actually needs replacing.

We cover Hayward (LO code, H-Series and HC Series), Pentair (ERR PS, MasterTemp and ETi 400), and Jandy (CHECK FLOW, JXi/JXiQ and Legacy series) — with brand-specific steps sourced directly from manufacturer service documentation.

$1,000 Monthly “Freebie Friday” Drawing

You Could Win Free ProTuff Gear — Every Month

Pool Care GuideMaintenance Checklists45 Pool Games eBookWeekly Tips & Deals

No Spam. Unsub anytime. Remain subscribed, remain eligible every month.

The 90% Rule: Why Most Flow Errors Aren’t the Heater’s Fault

Here’s the single most important thing to understand about pool heater flow errors: 90% of all heater service calls are caused by water flow problems external to the heater — dirty filters, closed valves, low pump speed. That’s not an estimate; that’s what heater schools at Laars (now Jandy), Raypak, and Hayward have taught technicians for decades.

Your heater is not a stand-alone device. It’s an “open boiler” — it’s cooled by the water flowing through it. If that flow drops below a minimum threshold, a safety device called the water pressure switch opens, cuts power to the burner circuit, and displays a fault code. This is by design. The heater is protecting itself from overheating damage.

That pressure switch typically closes at just 2–3 PSI. It’s one of the simplest, most robust parts in the system. When it’s “failing,” it’s usually not failing — it’s accurately reporting that something upstream has reduced flow below what the heater needs.

Key Takeaway

90% of heater flow errors are fixed by cleaning the filter or adjusting the pump — before replacing any part.

The three flow error codes this guide covers — LO (Hayward), ERR PS (Pentair), and CHECK FLOW (Jandy) — all mean the same thing at the hardware level: the water pressure switch circuit is open. Your job is to figure out why.

Start Here: The First 5 Things to Check

Run through this checklist before touching anything inside the heater. These five checks resolve the vast majority of flow errors without spending a dollar on parts.

1
Verify the pump is actually running

This sounds obvious, but it’s worth confirming. For multi-speed pumps, make sure the pump is set to high speed — low speed on a two-speed pump often can’t deliver enough flow to close the pressure switch. The heater will display a flow error any time the pump is off.

2
Clean the skimmer basket and pump strainer basket

Debris in these baskets is the single most common cause of suction-side flow restriction. Turn off the pump, remove and empty both baskets, then restart. This takes 5 minutes and costs nothing.

3
Check the filter pressure gauge

If the gauge reads 8–10 PSI above your normal “clean” baseline, backwash your sand or D.E. filter, or clean your cartridge filter. Even water that looks clear can carry invisible algae that clogs filter media faster than dirt does.

4
Check all valves — including the heater bypass valve

Closed or partially closed return-side valves will starve the heater of flow. Also check any external bypass valve; if it’s open too far, most of the water routes around the heater instead of through it, causing the pressure switch to open.

5
For variable speed pumps: increase RPM by 10–15%

A VSP set at the absolute minimum RPM to fire the heater will trip the pressure switch every time the filter gets even slightly loaded. Heaters need 20–40 GPM depending on BTU rating. Always program at least 15% more RPM than the bare minimum to build in headroom for filter loading.

Tools You’ll Need for Advanced Diagnosis
  • Multi-meter: To test for 24VAC at pressure switch terminals (electronic heaters) or 500–750mV (older millivolt/standing pilot models)
  • Pressure gauge: To verify filter back-pressure and flow
  • Pete’s Plug thermometer: Inserted into the drain plug hole to perform a temperature rise test and verify internal bypass operation

Hayward Heaters: Decoding the LO Code and FLo Error

Hayward uses the LO code (Limit String Open) to indicate that any safety circuit in the heater’s control loop has opened — including the water pressure switch. It appears on Universal H-Series (forced draft), HC Series, and older models. Heat pump models (HeatPro, Summit) display FLo or PS instead.

There’s also an HS code (High Sense) that you may see on HC Series heaters. This triggers when the inlet water temperature rises faster than 6°F in 60 seconds — a sign that water is moving so slowly through the exchanger that it’s getting dangerously hot before exiting. If you see HS, stop running the heater immediately and diagnose the flow issue.

⚠ Normal vs. Problem LO Code

LO is completely normal when your pump is off if your heater is wired to the line side of the circuit (continuous power). When the pump restarts, there is a mandatory 2-minute delay before the code clears and the heater fires. You can bypass this wait by pressing MODE to STANDBY and back to POOL or SPA after the pump has been running and primed.

Hayward LO Diagnostic Steps

1

Wait 2 minutes. If the pump just restarted, the LO code clears automatically after a 2-minute self-diagnostic delay. Do not assume a fault — just wait.

2

Check for bypass operation (bo). If the display shows “bo,” the heater is in Bypass Operation mode for remote thermostat control. To exit: press and hold the DOWN key, then press and hold the MODE key. Hold both for 3 seconds until “bO” disappears.

3

Test pressure switch voltage. With the pump running, use a multi-meter to check for 24VAC at one terminal of the water pressure switch, then check the other terminal. If you have voltage on the incoming terminal but not the outgoing terminal, the switch is open — indicating insufficient pressure or a failed switch.

4

The hand test (older models). Hold your hand over a return outlet fitting on the pool wall to restrict return flow. If the heater blower starts and the heater begins to fire when you cover the fitting but shuts off when you remove your hand, your eyeball fittings are too large. The back-pressure created by your hand is what the pressure switch needs. Replace with smaller eyeball fittings.

💡 Pro Tip

If you have a Variable Speed Pump and the minimum RPM to fire your Hayward heater is, say, 1,600 RPM, set your heater schedule at 1,850+ RPM. At the bare minimum, even slight filter loading will cause the pressure switch to “bounce” — cycling the heater on and off in rapid succession. That short cycling is hard on the igniter and burner components over time.

Pentair Heaters: Diagnosing ERR PS and the Service System LED

On MasterTemp and Max-E-Therm heaters, a water pressure switch fault shows up as ERR PS on the LCD display, or illuminates the Service System LED. The LED approach appears on older 5-button models; newer 6-button RS-485 connected heaters show the code on the display itself or on the IntelliCenter panel.

On the ETi 400 High Efficiency model, you may see both ERR PS and ERR HLS (High Limit Switch) simultaneously — because when flow drops, the heat exchanger overheats and trips the high limit along with the flow fault.

Pentair Minimum Flow Requirements by Model

ModelMin. Flow (GPM)Min. Flow (LPM)
MasterTemp 175 / 20020 GPM76 LPM
MasterTemp 25025 GPM95 LPM
MasterTemp 30030 GPM114 LPM
MasterTemp 400 / ETi 40040 GPM151 LPM

Pentair Pressure Switch Adjustment

Pentair pressure switches are factory-set at 3 PSI for deck-level installations and have an adjustment range of 0–5 PSI. If your heater is installed more than 1 foot above or below the pool water level, the static head pressure will affect when the switch opens and closes — and you’ll need to adjust it.

  • Heater below pool level: Turn the star-wheel clockwise to raise the pressure setting. Without this adjustment, static water pressure may hold the switch closed even when the pump is off — and the heater may try to fire with no water moving.
  • Heater above pool level: Turn the star-wheel counter-clockwise to lower the setting, since the reduced static head means the switch needs to close at a lower threshold.
  • On the ETi 400, if water pressure falls outside the 0–5 PSI adjustment range entirely, a flow switch (rather than pressure switch) should be installed on the outlet piping.

Temperature Rise Test (ETi 400)

The ETi 400 manual specifies a temperature rise test as the most reliable diagnostic: subtract the inlet water temperature (shown on the LCD) from the outlet temperature (measured with a Pete’s Plug thermometer in the drain plug hole). The correct rise is 30°F ± 5°F.

  • Rise > 35°F: Flow is too low. The water is sitting too long in the heat exchanger. Clean the filter and increase pump speed.
  • Rise < 25°F: Flow is too high. Too much water is bypassing the exchanger or the pump is running faster than necessary.

Jandy Heaters: What CHECK FLOW and FL0 Really Mean

Jandy’s error message varies by model generation. All of them indicate an open pressure switch circuit due to insufficient water flow:

  • JXi Series (200, 260, 330, 400 BTU): Displays CHECK FLOW
  • JXiQ Series: Displays CHECK H20 FLOW
  • Legacy LRZ / Lite2 Electronic: Displays FAULT-NO FLOW or FL0
  • JRT / EE-Ti Heat Pumps: Displays FAULT-NO FLOW

Jandy JXi and JXiQ heaters require a minimum of 30 GPM and support a maximum of 100 GPM. The pressure switch on Legacy/Lite2 models is preset at 2 PSI (versus Pentair’s 3 PSI). If the heater is installed more than 15 feet below the pool surface, Jandy recommends consulting their technical support before adjusting the switch.

Jandy Diagnostic Steps

1

VSP check first. With a variable speed pump, add a 15% RPM buffer above whatever minimum fires the heater with a clean filter. A Jandy JXi at 30 GPM minimum might need you running the pump at 35 GPM equivalent to have stable operation through filter load cycles.

2

Voltage test (Legacy/Lite2). Check for 24VAC (electronic models) or 220–500mV millivolts (millivolt/pilot models) on both wires at the pressure switch. Voltage in but no voltage out means the switch is open — either from inadequate flow or a failed switch.

3

JXiQ: Use the Fluidra Pro app. Open the app, navigate to Connect to JXiQ Heater, and enter the 6-digit PIN from the heater display. The diagnostics screen shows real-time inlet/outlet water temperatures, transformer voltage, and safety loop status — far faster than any manual test.

4

Listen for pounding or knocking. If the heater makes a loud banging noise when it runs, the internal bypass or Thermal Regulator Valve (TRV) has likely failed. This is a separate issue from a basic flow error — see the TRV section below.

Hayward
H-Series / HC-Series

Pentair
MasterTemp / ETi 400

Jandy
JXi / JXiQ / Legacy

Error CodeLO (H-Series, HC Series)
FLo / PS (heat pumps)
HS = dangerous low flow
Switch SettingFactory: 3 PSI
Min Flow20–40 GPM (by BTU)
Unique Note2-min delay on restart; “bo” = bypass mode
Error CodeERR PS (LCD display)
Service System LED (5-btn)
ERR HLS with overtemp
Switch SettingFactory: 3 PSI (0–5 PSI range)
Min Flow20–40 GPM (by model)
Unique NoteStar-wheel adjustment; temp rise test (30°F ± 5°F)
Error CodeCHECK FLOW (JXi)
CHECK H20 FLOW (JXiQ)
FAULT-NO FLOW / FL0
Switch SettingFactory: 2 PSI (Legacy)
Min Flow30 GPM minimum
Unique NoteFluidra Pro app for JXiQ diagnostics; TRV opens at 120°F

Replacing a Pressure Switch: Brand-by-Brand Guide

If you’ve cleaned the filter, verified pump flow, and tested the switch with a multi-meter — and the switch still won’t close — it’s time to replace it. The cost is modest ($50–$100 in parts), but the safety stakes are high: a pressure switch that’s adjusted too low can allow the heater to fire with insufficient flow, turning the heat exchanger into a pressure cooker. If your heater is still under warranty, have a licensed technician do this work.

❗ Never Bypass the Pressure Switch

Jumpering or bypassing the pressure switch terminals to force the heater to fire is extremely dangerous. If water flow is truly absent, the heat exchanger will overheat and can explode or catch fire. Manufacturer manuals explicitly state: “Do not bypass the Water Pressure Switch or render it inoperable.”

BrandPart NumberReplacement StepsTime
HaywardFDXLWPS1930
(H-Series)
1. Turn off power, gas, and pump. 2. Remove side access panel (4 screws). 3. Disconnect wiring harness terminals and siphon loop tubing from the switch. 4. Use two 1/2″ open-end wrenches to unscrew the switch. 5. Apply pipe thread sealant to new switch threads. 6. Install and reverse steps.~30 min
Pentair42001-0060S
(MasterTemp)
1. Disconnect power to heater. 2. Locate switch inside water manifold assembly. 3. Disconnect wiring. 4. Unscrew and replace switch. 5. Adjust star-wheel if heater is above or below pool level. 6. Test with pump running: ERR PS should clear.~30 min
JandyR0457001
(JXi/JXiQ)
1. Set heater to OFF. 2. Remove 7 side panel screws to access the water pressure switch. 3. With pump running, test for switch closure with voltmeter. 4. If open: disconnect and replace the switch and siphon loop assembly. 5. Confirm CHECK FLOW clears on restart.~45 min

Cost estimate: $50–$100 for DIY parts. A professional service call for pressure switch replacement typically runs $250–$400 including labor.

The Banging Noise Problem: TRV and Internal Bypass Failures

If your heater is making a loud banging, knocking, or bouncing sound — or if it short-cycles (fires for a few minutes, shuts off, restarts) — you’re likely dealing with a failed Thermal Regulator Valve (TRV) or internal bypass valve, not just a dirty filter.

Here’s what’s happening: the internal bypass valve is spring-loaded to direct just enough water through the heat exchanger for optimal heat transfer, while routing the rest around it. When it fails, too little water enters the exchanger — the water inside overheats, reaches boiling point, and turns to steam. That steam pressure creates the loud banging or pounding you hear. In extreme cases, the entire heater bounces on its pad.

🔥 Stop the Heater Immediately

A heater that is knocking loudly is flash-boiling water inside the heat exchanger. Continued operation can permanently warp the manifold, crack headers, or cause the heat exchanger to fail entirely. Turn the heater off and do not restart it until the internal bypass is repaired.

How to Test Your TRV

The TRV should open at 120°F. To test it: remove the TRV from the heater (it’s accessible via the manifold access door/cap). Place it in a pot of water with a thermometer and heat the water. The valve should visibly open by the time the water reaches 120°F. If it stays closed past 120°F, or doesn’t open at all, replace it. Note: also test new TRVs — defective new parts have been documented in the field.

ComponentHayward Part #Pentair Part #Jandy Part #
TRV / Thermal Regulator KitR0054900 (internal bypass)77707-0010 (kit w/ spring, cap)R0589700 (JXi); R0589701 (JXiQ)
Internal Bypass ValveSee service manual77707-0001R0589800
💡 Pro Tip

On a Pentair MasterTemp, you can inspect the bypass valve without pulling the manifold: remove the TRV (thermal regulator), then stick your fingers through the opening and feel toward the top-center of the cavity. You should feel a solid round button-like disk — that’s the bypass valve. If you feel nothing or feel something dangling, the bypass is broken and the manifold needs to come off for full replacement.

DIY safety level: TRV replacement is a reasonable DIY task for a mechanically inclined owner ($80–$150 in parts). Internal bypass valve replacement requires manifold disassembly and carries real risk of flooding or heat exchanger damage if reassembled incorrectly — this is a licensed technician job ($300–$500). The Jandy manual specifically states: “Incorrect service of this heater can result in personal injury or damage to property. The heater must be serviced only by a qualified professional service technician.”

Preventing Flow Errors: Maintenance Schedule and Water Chemistry

The best heater service call is the one you never have to make. Since 90% of flow errors trace back to the external hydraulic loop, your maintenance routine is your first line of defense.

Maintenance Schedule

✅ Weekly
  • Empty skimmer basket and pump strainer basket — the #1 cause of flow restriction
  • Check filter pressure gauge; if 8–10 PSI above clean baseline, clean or backwash the filter
✅ Monthly
  • Inspect pool water level — it should be at mid-tile; low water causes the pump to draw air
  • Verify the skimmer weir (flap) moves freely and isn’t stuck vertically
  • Check for air bubbles at return jets (indicates a suction-side leak)
✅ Seasonally (Spring/Fall)
  • Inspect blower intake and exhaust vents for rodent nests, spider webs, mud dauber dirt — these block airflow and cause cascade faults
  • Test the pressure relief valve: lift the lever while pump is running; water should flow freely. If it doesn’t open, replace it
  • Inspect the TRV before each pool season. Scaling or corrosion on the TRV is a leading indicator of poor water balance. Jandy explicitly recommends annual TRV inspection in their service manual
  • Verify VSP RPM settings with a clean filter and confirm the heater fires reliably at your programmed speed

Keeping debris cleared from your pool proactively reduces filter clogging and protects heater flow. A pool net and brush used consistently every week means your filter runs cleaner and longer between backwashes.

ProTuff Pool Net leaf rake for pool maintenance

Pool Maintenance
ProTuff Pool Net

Keep leaves and debris out of your skimmer basket before they restrict flow to the heater. The ProTuff leaf rake is built for daily use with the 490 Promise warranty.

Water Chemistry: The Silent Threat to Heater Flow

Unbalanced water is the other half of the flow problem — and it’s entirely invisible until the damage is done. Scale buildup inside the heat exchanger tubes acts as insulation, slowing water flow and causing the pressure switch to trip even when the pump is running normally. Corrosive water (low pH) pits the copper tubes and creates debris that blocks internal passages.

ParameterIdeal RangeToo LowToo High
pH7.4 – 7.6Erodes copper heat exchanger tubes; acidic water corrodes all metalsCalcium scale coats exchanger tubes; reduces flow and efficiency
Total Alkalinity80 – 120 ppmpH swings wildly; corrosive conditions are unpredictableHeavy calcium scale in hot exchanger tubes
Calcium Hardness200 – 400 ppmWater leaches calcium from heater materials; corrosive to metalsCalcium scale clogs exchanger; worsens near heat exchanger temperatures (~140°F)
Free Chlorine1.0 – 3.0 ppmAlgae growth; can clog filter rapidlyAbove 5 ppm: rapidly corrodes copper heat exchanger fins

Pro Tip: Never Use the Skimmer as a Chlorinator

Never put chlorine tablets in your skimmer basket. When the pump turns off, concentrated chlorine back-siphons into the heater, flooding the heat exchanger with acid. One season of this practice can destroy a heat exchanger that would otherwise last 10 years. All three major heater brands — Hayward, Pentair, and Jandy — call this out explicitly in their manuals as a warranty-voiding action. Install an inline chlorinator downstream of the heater, always.

ProTuff Pool Brush Head for regular pool maintenance

Pool Maintenance
ProTuff Pool Brush Head

Regular brushing keeps algae off walls and surfaces, reducing bioload on your filter. Less filter resistance means more consistent flow to your heater — and fewer nuisance ERR PS, LO, and CHECK FLOW codes.

When to Call a Pro (and What to Expect to Pay)

Most flow errors are DIY territory — clean the filter, adjust the pump, maybe replace an inexpensive pressure switch. But there are clear signs that it’s time to put down the multi-meter and call a licensed pool heater technician.

🔒 Stop DIY — Call a Pro if You See Any of These
  • Gas smell or yellow/orange flames: A yellow or lazy flame is a combustion problem — call a gas professional immediately.
  • Water pooling inside the heater cabinet: Internal leaks mean a cracked header, manifold, or failed heat exchanger gaskets — not a DIY repair.
  • EE (Hayward) or BD1 (Raypak) error codes: These indicate internal circuit board failure, requiring specialized tools and parts.
  • Black soot on the heat exchanger fins: Sooting is a fire hazard and indicates combustion problems that require professional diagnosis.
  • Loud, continuous banging after cleaning filter/adjusting pump: Internal bypass failure requiring manifold disassembly.

What You’ll Pay

RepairDIY Parts CostProfessional Total
Filter cleaning / pump adjustment$0$150–$250 (diagnostic call)
Pressure switch replacement$50–$100$250–$400
TRV replacement$80–$150$300–$500
Internal bypass valve replacementPro only$300–$500
Heat exchanger replacementPro only$2,000+ (often replace heater)

Warranty note: All three major brands void the warranty for repairs by unlicensed individuals, use of non-genuine parts, and heat exchanger damage caused by improper water chemistry (pH outside 7.2–7.8, or chlorine above 5 ppm). If your heater is still under warranty, always use a licensed technician to preserve coverage.

Temporary Workarounds While Waiting for Parts or Service

  • Install or activate an external heater bypass valve: This routes water around the heater so your pump and filter continue to circulate the pool while the heater is offline. Without circulation, algae can take hold within 24–48 hours in warm weather.
  • Use a robotic pool cleaner or submersible pump: If the main pump must stay off, these keep water moving and chemicals distributed.
  • Chemical maintenance: Lower pH to 7.2 and shock the pool to keep water sanitary during reduced circulation. If you’re shocking the pool, do it at dusk or after dark — UV degrades unstabilized chlorine at approximately 1 ppm/hour in direct sunlight, which will make a shock ineffective by morning.

Frequently Asked Questions

Why does my pool heater show LO when the pump is off?

This is completely normal behavior for Hayward heaters wired to continuous (line-side) power. The LO code means the limit string is open — which it always is when the pump is off and no water pressure is present. When your pump restarts, the LO code clears automatically after a mandatory 2-minute self-diagnostic delay. If LO persists for more than 2 minutes after the pump is running and primed, that’s when you have an actual flow problem to diagnose.

What is the minimum GPM my pool heater needs to fire?

It depends on the heater’s BTU rating. For Pentair MasterTemp and Hayward H-Series: 175,000–200,000 BTU models need 20 GPM; 250,000 BTU needs 25 GPM; 300,000 BTU needs 30 GPM; 400,000–500,000 BTU needs 40 GPM. Jandy JXi models (all BTU sizes) require a minimum of 30 GPM. Important: always program your variable speed pump at least 15% above these minimums to build headroom for filter loading over time.

How do I know if my pressure switch needs replacement or just adjustment?

Test it with a multi-meter while the pump is running: you should see 24VAC on both the incoming and outgoing terminals (or 500–750mV on millivolt systems). If you have voltage on one side but not the other, the switch is open. First, verify that flow is actually adequate — clean the filter and baskets. If flow is confirmed adequate and the switch still won’t close, try adjusting the star-wheel (Pentair) or adjustment screw (others) first. Switches are robust and rarely fail outright; adjustment is usually the right fix before replacement. Replace only if adjustment doesn’t resolve it after verified adequate flow.

Why is my pool heater making a banging or knocking noise?

A loud banging or knocking noise from a pool heater is almost always caused by water flash-boiling inside the heat exchanger. This happens when water flow through the exchanger drops so low that the water reaches boiling temperature before it exits. The most common cause is a failed internal bypass valve or Thermal Regulator Valve (TRV), which normally diverts just enough water through the exchanger while bypassing the rest. Turn the heater off immediately — continued operation with flash-boiling can permanently warp the manifold or crack the heat exchanger. Do not restart until the internal bypass or TRV is inspected and repaired.

Can I bypass the pressure switch to get my heater to fire?

No — and this is critically important. Bypassing the water pressure switch is explicitly prohibited by all manufacturers and is extremely dangerous. If water flow is truly absent or inadequate, the heat exchanger has no cooling and will rapidly overheat. This can cause an explosion, fire, or catastrophic heat exchanger failure. All three major brands — Hayward, Pentair, and Jandy — state in their manuals: “Do not bypass the Water Pressure Switch or render it inoperable. Severe personal injury, death, or substantial property damage can result.” Fix the underlying flow problem instead.

What water chemistry levels damage a pool heater heat exchanger?

According to manufacturer guidelines, the three most damaging conditions are: (1) Low pH below 7.2, which corrodes the copper heat exchanger tubes and all metals in the water path; (2) High pH above 7.8 combined with high calcium hardness, which causes calcium scale to coat the exchanger tubes and restrict flow; and (3) Free chlorine above 5 ppm, which rapidly corrodes the copper fins — especially dangerous if chlorine tablets are placed in the skimmer, where concentrated chlorine back-siphons into the heater when the pump is off. Keep pH at 7.4–7.6, total alkalinity at 80–120 ppm, and free chlorine at 1–3 ppm to protect the heat exchanger from all three threats.

How often should I inspect the Thermal Regulator Valve (TRV)?

Jandy recommends inspecting the TRV before every pool season, typically in the spring when you open the pool. The TRV is actually a useful indicator of your overall water balance: calcium scale on the TRV means your water is scale-forming (high pH or alkalinity); corrosion on the TRV means your water is acidic. If the TRV shows either sign, replace it and correct your water chemistry — because the same conditions affecting the TRV are also affecting your heat exchanger tubes. A TRV that doesn’t open by 120°F should always be replaced regardless of visible condition.

Disclaimer

This article is for informational purposes only. Pool heater troubleshooting and repair involves high-voltage electricity, natural gas or propane, and pressurized water systems. Improper repairs can cause serious injury, death, fire, explosion, or carbon monoxide poisoning. Always disconnect power and gas before servicing any heater component. When in doubt, consult a licensed pool heater technician. ProTuff Products is not responsible for any injury, damage, or loss resulting from the use of this information. Warranty work should always be performed by an authorized service technician.

$1,000 Monthly “Freebie Friday” Drawing

You Could Win Free ProTuff Gear — Every Month

Pool Care GuideMaintenance Checklists45 Pool Games eBookWeekly Tips & Deals

No Spam. Unsub anytime. Remain subscribed, remain eligible every month.