You press “Spa” on the panel and nothing happens. Or worse, one valve turns and the other one doesn’t, so the spa slowly drains into the pool overnight. A 24-volt valve actuator that won’t rotate is one of the most common automation failures pool owners hit in the fall, because actuators that sat in one position all summer stick the first time you ask them to move.
The good news is that most of these failures are not broken parts. They are switches in the wrong position, disengaged handles, and $5 fuses. This guide walks the same diagnostic order a service tech uses, brand by brand, with the exact voltage readings that tell you where the problem lives.
Roughly 80% of “actuator won’t rotate” calls come down to four things: a toggle switch bumped to OFF, a manual override handle left pushed down, a blown 3.15A or 4A low-voltage fuse on the automation board, or two actuator cords plugged into swapped sockets. Check all four before you open anything.
- What a Stuck Actuator Actually Does to Your Pool
- Start Here: Four Checks That Solve 80% of Cases
- Tools and the Exact Readings That Matter
- Symptom-by-Symptom Diagnosis
- Brand-by-Brand Diagnostics
- Blown Fuses and Finding the Shorted Actuator
- Microswitches, Cams, Gears, and Bound Stems
- What You Can Fix and What Needs a Pro
- Manual Override: Keep Filtering While You Wait
- Prevention: Lube, Chemistry, and Weather Sealing
- Warranty Traps and Red Flags
- Frequently Asked Questions
You Could Win Free ProTuff Gear — Every Month
No Spam. Unsub anytime. Remain subscribed, remain eligible every month.
What a Stuck Actuator Actually Does to Your Pool
A pool-and-spa combo system uses at least two 24-volt actuators. One sits on the suction (intake) valve and decides where the pump pulls water from. The other sits on the return valve and decides where filtered water goes back to. Your automation panel commands both at the same time.
When one of those two fails to rotate, the system ends up in a split configuration it was never designed to run in. The pump pulls from the spa and returns to the pool, which drains the spa. Or it pulls from the pool and returns to the spa, which overflows the spa across the deck. Either way you find out the next morning, not while it is happening.
There is a second, quieter failure mode. A valve that stops halfway restricts flow through the whole system. That triggers a flow fault on the heater — a Jandy JXi shows CHECK FLOW, and a Hayward heat pump shows FLo — and the heater refuses to fire. People chase a heater problem for a week when the real fault is a diverter sitting at 45 degrees.
This symptom clusters in the fall. An actuator that held one position all summer builds scale on the valve stem and loses its grease film. The first cold morning you switch to spa or heat mode, the gear train has to break that bond, and a worn plastic gear stack often loses.
Start Here: Four Checks That Solve 80% of Cases
Work these in order. Each one takes under five minutes and none of them require a tool more serious than a screwdriver.
On the bottom or rear of the actuator housing is a three-position toggle switch marked ON1 – OFF – ON2. If it got bumped to the center OFF position, the motor gets no power at all and the actuator is simply dead. If it is on ON1 when it should be on ON2, the valve rotates opposite to what the panel commands.
Above the handle is a locking knob. If someone loosened that knob and pushed the handle down, the internal drive shaft disengaged from the gear train. The motor will hum and turn internally, but the valve diverter never moves. This is the single most common reason for “the motor runs but nothing happens.”
A 3.15A glass fuse on Jandy boards, or a 4A mini-blade fuse on Hayward boards, protects the 24 VAC valve circuit. One momentary jam or one pinched wire blows it, and every actuator on the system goes dead at once. If none of your valves move, suspect this before you suspect three simultaneous actuator failures.
If the suction actuator cord is plugged into the RETURN socket and the return cord into SUCTION, both valves move on command but they move the wrong things. The system pulls from the spa and returns to the pool. This shows up right after someone services the panel, not out of nowhere.
If all four check out and the valve still will not rotate, you have a real fault. Move to the readings.
Tools and the Exact Readings That Matter
You need very little. A digital multimeter that reads AC volts and continuity, a #2 medium Phillips and a #1 small Phillips screwdriver, a short piece of 22 AWG jumper wire, and pool-safe silicone lubricant such as Jack’s 327. That is the whole kit.
What matters more than the tools is knowing what a healthy reading looks like. Here are the numbers that separate “this is fine” from “here is your fault.”
| Test point | Healthy reading | What a bad reading means |
|---|---|---|
| Actuator terminal pins (black to red, or black to white) | 24 VAC when the circuit is active | 0 VAC means the fault is upstream — fuse, relay driver, or harness |
| Transformer secondary (yellow wires) | 24 to 28 VAC on Jandy; 20 to 24 VAC on Hayward | Below range means a failing transformer or a blown secondary fuse |
| Transformer primary input | 105 to 130 VAC on Jandy; Hayward board input 110 to 130 VAC off the breaker | No primary voltage means a breaker or high-voltage wiring problem |
| DC control bus (AquaLink red terminal bar, pins 1 and 4) | 8 to 10 VDC | Out of range points at the main board power supply |
| Relay coil resistance | About 300 ohms | Open or shorted coil means a failed relay |
| Filter pressure during operation | Varies by filter type — a Jandy sand filter runs 5 to 15 PSI clean | A rise of 7 to 10 PSI above your own clean baseline means it is time to backwash or clean |
Putting the system in SERVICE mode does not make the actuator safe to open. It leaves 24 VAC live at the toggle switch. Before you remove a cover to work on internals, disconnect all high-voltage power to the automation panel at the breaker.
Symptom-by-Symptom Diagnosis
Actuator faults sort cleanly into four symptom groups. Find yours, work the ranked causes top to bottom, and stop when a test fails.
Symptom 1: Completely dead — no motor noise, no movement
Ranked by how often each one is the culprit: toggle switch in the center OFF position; blown low-voltage fuse on the automation board; blown transformer or lost 24 VAC secondary power; both internal microswitches tripped or stuck open; a failed relay driver chip such as the ULN2803A on the automation board; and finally seized or shorted motor windings.
Diagnose it in that order. Confirm the toggle switch is fully at ON1 or ON2. Set the meter to AC volts and measure at the board socket, black to red and then black to white — you should see 24 VAC when the circuit is active. If you read zero at the socket, the actuator is innocent and you test the board fuse for continuity. If the fuse is good, measure the transformer output across the yellow wires — 24 to 28 VAC on a Jandy power center, 20 to 24 VAC on a Hayward main power board. Only after all that do you unplug the actuator, pull the four cover screws, and test microswitch continuity across the common and normally-open or normally-closed spade terminals.
Symptom 2: Motor hums or spins, but the valve does not rotate
The handle is disengaged from the gear train far more often than anything else here. Behind that: stripped or cracked plastic drive gears, a sheared diverter shaft pin or broken rotor key, and calcified or dry valve stem O-rings creating friction the motor cannot overcome.
Unscrew the top locking knob counter-clockwise about four turns, pull straight up on the handle until it slides into the gear keyway, then hand-tighten the knob. If the motor still spins without moving the handle, pull the four cover screws and look at the main gear reduction stack for missing or stripped teeth. If the gears look fine, take the actuator off the valve body (four screws) and turn the valve stem by hand. If the stem binds, the problem is the valve, not the actuator.
Symptom 3: Rotates one direction only, or stops midway
This is almost always a limit-switch problem. One microswitch has failed or stuck mechanically, or a limit cam has slipped out of adjustment. Less commonly, a red or white switch-leg wire has broken inside the cord jacket, or the automation board’s driver channel for that valve has failed.
Open the lid and watch the two limit cams as the motor turns. The cam lobe should physically depress the microswitch roller arm right at the stop point. With power disconnected, use a jumper wire to short across the leads of the microswitch that is not working. If the motor moves when shorted, that switch is defective. If the cams and switches both test good, check continuity on the red and white conductors from the board connector all the way to the microswitch spade lugs.
Symptom 4: Pool and spa modes are reversed
Three causes, in order: the bottom toggle switch is on ON1 when it should be on ON2, the suction and return cords are swapped at the board, or the cams are set 180 degrees out of phase.
Try the toggle first — flip it to the opposite ON position and the motor immediately rotates 180 degrees to sync with the panel. That is a one-second fix. If that does not do it, check the socket labels on the board and confirm the intake actuator is in the INTAKE/SUCTION port and the return actuator is in the RETURN port.
Brand-by-Brand Diagnostics
The four checks above are universal. Past that point, each manufacturer has its own fuse layout, its own diagnostic mode, and its own part numbers. Here is what changes by brand.
- GVA-24 hardware: 24 VAC actuator using an Omron SS-5GL13T lever-arm microswitch.
- First step on OmniLogic and OmniPL: open the MSP screen and tap the Alarm icon. If you see “MPP Comm Loss” or “I/O EM Comm Loss,” fix the network communication before you touch the valve — the panel is not reaching the relay at all.
- If no comm alarms: go to Service Mode → Valve to energize the relay, then measure 20 to 24 VAC between pin 1–3 or pin 2–3 on the actuator terminal block.
- Main Power PCB fuses: top-left 4A pink fuse protects the 24 VAC valve actuator circuit; top-right 4A pink fuse protects the transformer primary; the yellow 20A fuse protects the transformer secondary output; the 5A AC fuse protects main board input power.
- Normal behavior, not a fault: OmniLogic, OmniPL, and S3 systems have an “Off for Valve Change” setting under the filter pump configuration. With it enabled the pump shuts off for 35 seconds whenever the valves change position, then restarts on its own. This is a menu option you turn on, not an automatic default.
- JVA 2444 hardware: uses an Omron SS-5T basic snap-action microswitch — the same switch as the Hayward unit but without the lever arm.
- Toggle switch: the ON1 – OFF – ON2 switch is on the actuator housing and is the first thing to check on any Jandy no-rotate call.
- Repeated 3.15A fuse blows: this has a defined isolation procedure, covered in full in the next section. Do not just keep replacing the fuse.
- Board sockets: the Power Center PCB has labeled Intake JVA, Return JVA, and Cleaner JVA sockets. Swapped cords produce a system that runs backwards.
- Voltage checks: the JVA pins should read 24 VAC from black to red or black to white. At the power center, the transformer secondary should read 24 to 28 VAC and the primary 105 to 130 VAC. Measure at the board, not at the socket.
- CVA24 model numbers by rotation: 263045 is the 180-degree unit, 263043 is 90-degree, and 263044 is 120-degree. Ordering the wrong rotation is a common mistake.
- IntelliValve, power LED blinking red and green with the service LED solid orange: the valve is mechanically stuck or bound by debris. Press the Mode button to clear the alert and reset position.
- IntelliValve, blinking blue LED: the actuator is sitting in Bootloader firmware mode.
- IntelliValve, blinking dial LED: it is reporting its current firmware version, not signaling a fault.
- Panel testing on EasyTouch, IntelliTouch, and IntelliCenter: press Mode on the load center to enter SERVICE mode, then press the Valve (V) button to toggle Pool and Spa while you measure for 24 VAC at the socket pins.
Blown Fuses and Finding the Shorted Actuator
A fuse that blows once is an event. A fuse that blows the instant you install it is a short, and replacing fuses will not find it. Here is the isolation procedure, written for the Jandy 3.15A case but structurally identical on Hayward’s 4A circuit.
Turn off all electrical power at the main breaker feeding the automation subpanel. Open the door and remove the dead-front faceplate to reach the main board.
Pull all JVA cords out of the Intake, Return, and Cleaner sockets on the Power Center PCB. You are removing every possible load from the 24 VAC valve circuit.
Replace the 3.15A fast-acting glass fuse on Jandy, or the 4A mini-blade fuse on Hayward. Turn the power back on with everything still unplugged.
A fuse that blows with zero actuators connected means the main Power Center PCB or its relay driver chips (the ULN2803A Darlington arrays) are shorted internally. That is a board replacement, and it is professional work.
Plug one JVA back into the Intake socket and command a Pool/Spa mode switch. If the fuse survives, power down, add the next cord, and repeat. Keep going until the fuse blows — the actuator you just connected is the shorted one.
Pull the cover and inspect for internal water intrusion, rusted gears, or a wire pinched against the motor casing. Water in the bottom shell is the usual answer, and it means the shaft pass-through seal failed.
A 3.15A glass fuse or a 4A mini-blade fuse costs $3 to $10. Having a pro do this same isolation runs roughly $150 to $250, and the whole job takes 10 to 15 minutes once the panel is open.
Microswitches, Cams, Gears, and Bound Stems
Once you have proven the electrical supply is good, the remaining faults are mechanical. These are genuinely DIY-friendly repairs on low-voltage equipment, and the parts are cheap.
Replacing a failed microswitch
Disconnect all power first — remember that SERVICE mode leaves 24 VAC live. Remove the handle, the locking knob, and the four stainless cover screws, then lift the top cover off. Test each of the two limit microswitches for continuity across the spade terminals while you press the switch arm by hand.
To swap a bad one, slide the .110-inch spade connectors off carefully, unscrew the two small Phillips mounting screws, and install the replacement in exactly the original orientation. Jandy JVA 2444 units take an Omron SS-5T; Hayward GVA-24 units take the lever-equipped Omron SS-5GL13T. Switches run $5 to $15 and the job takes 15 to 20 minutes.
Bending or twisting the small metal terminals on an Omron microswitch stresses the internal snap-action contacts. The switch will work on the bench and then fail within weeks. Slide the connectors straight off and straight on.
Realigning the limit cams
Rotate the central shaft until the arrow mark on the cam lines up with the pointer above the microswitch arm. The top cam sets the right stop position and the bottom cam sets the left stop. Adjust both until the actuator hits exactly 90 or 180 degrees, then tighten the center cam nut. If a cam has slipped, loosen the nut, reposition it so the lobe depresses the switch at the true stop point, and retighten.
Stripped gears and bound valve stems
Take the four mounting screws out and lift the actuator off the valve stem. Turn the stem by hand. If it binds, the problem is the valve — remove the eight valve cover screws, pull the diverter assembly, clean out debris and calcification, replace damaged O-rings, and coat everything with pool silicone lube. If the stem turns smoothly, the fault is inside the actuator. Open the casing, inspect the gear stack for broken teeth or rust, clean out the contaminated old grease, apply fresh heavy silicone grease, and drop in a replacement gear train. Gear kits run $25 to $45; the equivalent service call is $175 to $275.
Before you reinstall the lid, put a light coat of thick silicone grease on the handle shaft pass-through and the perimeter casing gasket. Nearly every rusted gear stack started as rainwater running down the shaft. Two minutes of grease at reassembly buys you years.
What You Can Fix and What Needs a Pro
The dividing line is voltage. Everything on the 24 VAC side is homeowner territory. Everything on the 120V/240V side is not.
| Safe for homeowners (24 VAC low voltage) | Requires a licensed professional |
|---|---|
| Flipping toggle switches (ON1 / OFF / ON2) | Replacing main automation PCBs or transformer assemblies |
| Engaging or disengaging the manual handle override | Any 120V or 240V panel wiring and subpanel breakers |
| Replacing Omron SS-5T or SS-5GL13T microswitches | Diagnosing shorted board traces or soldering driver ICs |
| Replacing 3.15A or 4A low-voltage fuses | Heater interlock, gas valve relay, or fireman switch wiring |
| Swapping JVA plugs between low-voltage sockets | Cutting out and replumbing a cracked PVC valve body |
| Lubricating valve stem O-rings and gear trains | Anything you would need to open the high-voltage compartment for |
Cost expectations
Parts are cheap. Expect roughly $3 to $10 for mini-fuses, $5 to $15 for Omron microswitches, and $25 to $45 for gear replacement kits. Be aware that neither component pricing nor professional labor rates are published in the manufacturer manuals, so treat every dollar figure in this guide as a general market estimate rather than a quote. As a rough frame, the simplest diagnostic visits tend to land in the $75 to $150 range and mechanical repairs in the $150 to $275 range, but regional labor rates vary widely.
Five mistakes that turn a $10 fix into an $800 one
Probing live terminals carelessly. Jumping raw wire across live 24 VAC terminals, or mishandling high-voltage leads, can blow board relays, destroy the ULN2803A driver ICs, or kill the main automation PCB outright. That is a $300 to $800 mistake in exchange for saving five minutes.
Using the wrong mounting screws. Actuator mounting screws have brand-specific thread pitches. Forcing a Hayward screw into a Jandy valve body strips the plastic female threads, and a stripped valve body means cutting pipe and replumbing the whole assembly.
Over-tightening into PVC. Driving lid or actuator screws with a power tool fractures the plastic casing and gives you a high-pressure leak. Start every screw counter-clockwise by hand until it drops into the original thread, then snug it by hand only.
Bending microswitch leads. Covered above, and worth repeating because the failure shows up weeks later when you have forgotten what you did.
Using the wrong sealant or lubricant. Valve manuals are blunt about this: do not use petroleum-based products, and use only sealant compounds suited for plastic pipe. On O-rings and seals, use silicone-based lubricant only — other lubricants damage valve components. Hayward specifies Jack’s Lube No. 327 for cover O-rings by name.
Manual Override: Keep Filtering While You Wait
If an actuator is dead and the part is three days out, you do not have to shut the pool down. You can lock the valve manually and keep filtering safely.
Flip the actuator toggle switch to OFF. Unscrew the top locking knob counter-clockwise four full turns. Then push down firmly on the locking knob — not the handle — to disengage the internal drive gear.
Rotate the valve handle so the side embossed with “OFF” faces and blocks the spa port. That sends all suction and return flow through the pool, so the spa neither drains nor overflows while you filter.
Put the intake valve fully to pool, then set the return valve so the “OFF” tab only partially blocks the spa port — roughly 90% pool and 10% spa. That keeps water turning over in the spa while the pool filters.
When the new part arrives, pull the handle back up into the gear keyway and hand-tighten the locking knob before you flip the toggle back to ON1 or ON2. An actuator left disengaged will hum happily forever and move nothing.
Prevention: Lube, Chemistry, and Weather Sealing
Actuators fail for three reasons: water gets inside the casing, the gear train binds, or chemistry eats the valve seals. All three are preventable on a schedule. How often you actually need to lubricate depends on how often the valve actuates, plus your water chemistry, water quality, and water temperature.
- ☐ Every 3 months: Inspect the valve seals and the small shaft seal to be sure they are well lubricated, and re-apply pool-safe silicone lubricant such as Jack’s Lube No. 327. Valve manuals specify this three-month interval directly.
- ☐ Every 3 months: Confirm you are not using Vaseline or any petroleum-based lubricant — petroleum degrades rubber O-rings and spider gaskets.
- ☐ Annually (general practice, not a published interval): Remove the actuator top cover and inspect the perimeter sealing gasket. Grease the handle shaft pass-through and the casing gasket.
- ☐ Annually: Pull the actuator, disassemble the PVC valve body, and clean and grease the internal square seal and diverter shaft O-rings.
- ☐ Every 2 to 3 years (general practice, not a published interval): Inspect the internal drive gears for moisture, rust, or worn teeth, and re-grease the gear stack with heavy silicone grease.
- ☐ Once, at setup: On Hayward OmniLogic, OmniPL, or S3, turn on “Off for Valve Change” in the filter pump settings so the pump stops for 35 seconds during a valve turn.
The chemistry that protects your valves
Water balance is not just about comfort and clarity. Acidic water eats valve seals and metal motor components. Alkaline water lays down scale on the valve stem, which raises the torque the actuator has to produce until the plastic gears strip.
| Parameter | Target range | Why it matters for valves |
|---|---|---|
| pH | 7.2 – 7.8 (ideal 7.4 – 7.6) | Below 7.2 corrodes seals and motor metal; above 7.8 scales the valve stem and strips gears |
| Total alkalinity | 80 – 120 ppm | Buffers pH so it does not swing into the damaging ranges |
| Calcium hardness | 200 – 400 ppm | High calcium drives the scale that binds diverter stems |
| Total dissolved solids | Under 2,000 ppm | High TDS accelerates corrosion across the equipment pad |
Do not pour liquid chlorine or acid into skimmers, and never install a chemical feeder or salt cell upstream of your filter or valves. Concentrated chemical back-siphoning through a valve swells the rubber seals and destroys spider gaskets. Install in-line chlorinators downstream of all equipment, with a corrosion-resistant check valve between the heater or valves and the feeder.
When you do shock the pool, do it at dusk or after dark. Direct sun destroys up to 90% of unstabilized chlorine within about two hours, so a midday shock loses most of its punch before it finishes working. Shocking after sundown lets the full dose act overnight and keeps you from over-dosing to compensate.
Brushing is part of this too. Scale does not only build on the valve stem — it builds on surfaces first, and a pool that gets brushed regularly gives you an early read on whether your calcium and pH are drifting.

Consistent brushing is how you catch calcium drift before it hardens onto equipment. This brush head is covered by our 490 Promise, so if it ever fails you, we replace it — you buy it once and keep brushing.
Check these at the same time
While you are at the pad, look at the in-line check valve between the heater or valves and the chemical feeder. If its spring or flapper has failed, concentrated chlorine back-siphons into the valve body every time the pump shuts off, and it will ruin your diverter seals. Also check the heater’s flow switch behavior, since a partially stuck valve is a common hidden cause of CHECK FLOW and FLo faults. Finally, inspect the female threads on the PVC valve body where the actuator mounts, and never mix mounting screws between brands.
Warranty Traps and Red Flags
Two things can turn a routine repair into an expensive surprise. The first is warranty language. The second is a symptom that means the actuator is a victim, not the cause.
What voids the warranty
Manufacturers enforce sales-channel rules that catch a lot of owners off guard, and the rules are not the same across brands. Jandy and Fluidra state explicitly that their limited warranty does not apply to products bought through the internet or other e-commerce platforms, excepting Jandy-branded valves under three inches in diameter, parts, and accessories. Jandy also requires installation and service by a contractor licensed and qualified in pool equipment where the local jurisdiction requires one. Pentair is looser: a product not installed by a qualified installer still carries a 60-day parts warranty, and buying from an authorized Pentair online reseller gets you one year on parts. Hayward splits its lines — Open Line products carry their standard parts warranty whether you install them yourself or not, while professional installation matters mainly for extended labor coverage on Expert Line products. Check your own brand’s current terms rather than assuming.
Warranties also exclude specific damage causes: freeze damage inside un-winterized valve bodies, chemical corrosion from bad water balance or from feeders plumbed upstream of the valves, and water intrusion from missing gaskets, loose housing screws, or a flooded equipment pad. Note the pattern — every one of those is preventable with the maintenance schedule above.
Three red flags that mean something bigger is wrong
A fuse that blows the moment you install it. This is a hard short, either on the main PCB or inside one of the actuator motors. Run the isolation procedure rather than burning through fuses.
Water pooling inside the actuator shell. The shaft pass-through seals have failed. Water corrodes the internal copper wiring, shorts the microswitches, and rusts the motor bearings. Fixing the switch without fixing the seal just resets the clock.
Melted, warped, or fractured PVC valve bodies. This comes from severe chemical corrosion — usually a chlorinator plumbed in the wrong place — or from dry-running heat. There is no repair. The valve assembly gets cut out and replumbed.
Frequently Asked Questions
Why does my spa drain into the pool overnight?
This happens when the return or suction actuator fails to rotate fully back to pool mode, or the bottom toggle switch is set to OFF or the handle is disengaged. If the diverter is left partly open to the spa on the suction side while water returns to the pool, the pump slowly empties the spa into the pool.
Why does the actuator motor hum or spin, but the valve won’t turn?
The handle shaft has been manually disengaged from the internal drive gears, or the plastic reduction gears have stripped. Unscrew the locking knob four turns, pull straight up on the handle until it clicks into the gear keyway, and hand-tighten the knob. If it still spins freely, the gear train teeth are stripped and need replacing.
Can I manually turn the pool and spa valve if the actuator stops working?
Yes. Flip the bottom toggle switch to OFF, unscrew the top locking knob counter-clockwise four full turns, and push down on the locking knob — not the handle — to disengage the gear train. You can then turn the handle by hand to isolate the pool or the spa while you wait for parts.
Does it matter which socket I plug the actuator cord into on the control board?
Yes, it matters completely. Plugging the suction actuator into the RETURN socket, or the reverse, makes the whole system run backwards. Triggering spa or spillway mode then rotates the wrong valve, which either drains the spa into the pool or overflows the spa across your deck.
My board fuse blows again the second I replace it. What now?
You have a hard short, so stop replacing fuses. Kill power, unplug every actuator cord from the board, install a fresh fuse, and restore power. If it blows with nothing connected, the board or its driver chips are shorted. If it holds, reconnect actuators one at a time to find the bad one.
What voltage should I read at the actuator terminals?
You should read 24 VAC between black and red, or black and white, while the circuit is active. The transformer secondary reads 24 to 28 VAC on a Jandy power center and 20 to 24 VAC on a Hayward board. Reading zero at the board socket means the fault is upstream of the actuator — check the fuse and transformer before blaming the valve.
How often should I lubricate my valve actuators?
Lubricate the actuator shaft and valve stem O-rings with pool-safe silicone every three months. Once a year, open the top cover to inspect and grease the perimeter gasket and shaft pass-through. Every two to three years, inspect and re-grease the internal gear stack. Never use petroleum products anywhere in that process.