A UV or AOP sanitizer is the most fragile thing on your equipment pad. Inside every Hayward HydraPure, Jandy X Series AOP, and Pentair BioShield is a glass quartz sleeve wrapped around a glass lamp, sitting in a vessel full of water. Leave that water in place through one hard freeze and the ice can crack the sleeve, the lamp, or the vessel itself.
All three manufacturers say the same thing in their manuals: freeze damage is not covered under warranty. This guide walks you through exactly how to winterize a pool UV AOP system, brand by brand, using the steps each manufacturer publishes, so you open in spring with working equipment instead of a parts bill.
- Why UV and AOP Units Need Special Care
- When to Shut Down Your UV or AOP System
- Prep the Pool Before You Touch the Equipment
- The Right Order of Operations
- Brand-by-Brand Quick Reference
- Hayward HydraPure and HydroRite Walkthrough
- Jandy X Series AOP Walkthrough
- Pentair BioShield Walkthrough
- Cleaning and Storing Quartz Sleeves and Lamps
- Mistakes That Crack Glass and Void Warranties
- Status Lights and Service Intervals to Check Before Closing
- Frequently Asked Questions
You Could Win Free ProTuff Gear — Every Month
No Spam. Unsub anytime. Remain subscribed, remain eligible every month.
Why UV and AOP Units Need Special Care
A UV system passes pool water past an ultraviolet lamp. An AOP (advanced oxidation process) system pairs UV light with ozone. Either way, the lamp sits inside a quartz sleeve or quartz tube, which is a thin glass shield that keeps water away from the lamp and the electrical parts.
Water expands about 9% when it turns to ice. Inside a sealed vessel, that expansion has nowhere to go. Hayward’s HydroRite manual spells out the result: ice inside the vessel can break the glass quartz sleeve, the UV lamp, or the vessel itself. It also states that damage from freezing, including broken glass, the vessel, or water damage to other parts caused by freezing, is not covered under the limited warranty.
Jandy says the same about its X Series and Offline AOP systems: damage caused by a broken quartz tube is not covered. Pentair’s BioShield guide states that damage due to freezing is not covered under warranty.
There is a second, slower failure too. A cracked sleeve lets water into the dry electrical chamber. Hayward’s guidance warns that this water attacks the electrical components, which then fail and need replacing. So one cracked piece of glass can take out the electronics as well.
Hayward, Jandy, and Pentair all exclude freeze damage from their warranties. Draining the vessel and getting the glass indoors is the only protection you have.
When to Shut Down Your UV or AOP System
Timing matters in both directions. Close too early and you waste swim season. Close too late and a cold snap does the damage for you.
- General pool closing: Pool closing guidance in our source library says to wait until the water gets down to 60°F or lower. It also says to start well before danger of freeze, so all equipment has time to fully drain and dry.
- Pentair BioShield: Pentair recommends shutting the UV system down when the temperature consistently falls below 40°F (4°C). Return it to service when temperatures consistently return to 40°F or greater.
- Jandy X Series AOP: Jandy says that if the pool shuts down for winter and the AOP unit will stay exposed to freezing temperatures, the unit must be drained to prevent freeze damage to the wetted parts.
In mild climates where freezes are short and rare, Pentair’s equipment guidance says you can run the filtering equipment all night during temporary freezing conditions. Moving water does not freeze. But that only works while you have power. A storm outage on a freezing night leaves standing water in every vessel on the pad.
Pentair’s pump manual puts it plainly: you are responsible for determining when freezing conditions may occur. If a hard freeze is in the forecast and the pool is not in use, winterize now rather than counting on the pump to keep water moving.
Prep the Pool Before You Touch the Equipment
Close a clean pool. A dirty pool going under a cover becomes a swamp by spring. Pool closing guidance from our source library lays out this sequence before you drain any equipment:
- Clean and brush the pool. Vacuum and skim it.
- Test and balance the water: pH, alkalinity, and calcium hardness.
- Bring the water to shock level and hold it there for 24 hours with the pump running, so no algae blooms remain.
- Remove steps, ladders, and mats. Clean and store them.
- Lower the water below the skimmer. One source says about 3 inches below the skimmer opening for winter covers and 12 inches for safety covers. Another says 6 inches below the lowest return or skimmer opening. Follow your cover maker’s guidance.
Jandy’s AOP start-up guidance gives useful chemistry targets to aim for: pH between 7.4 and 7.6, and total alkalinity between 80 and 120 ppm.
Shock at dusk or after dark. Sunlight’s UV breaks down unstabilized chlorine at roughly 1 ppm per hour, so a midday shock burns off before it can do its job. Add it in the evening and let the pump run overnight.

Closing guidance starts with a full brush-down so algae has nowhere to hide under the cover. The ProTuff brush head is built heavy-duty for exactly that end-of-season scrub, and it is backed by the 490 Promise.

Fall leaves left in the water rot under the cover. Skim the pool one last time before closing, and keep the net handy to clear debris before the hard freeze. Every ProTuff net is covered by the 490 Promise.
The Right Order of Operations
Sequence matters on a UV or AOP unit because you are working with water, high voltage, and glass at the same time. Here is the order that keeps all three under control.
Turn off power to the UV or AOP unit, the pump, and any other pool equipment. Hayward’s HydraPure guide adds: make sure the pump will not re-activate. That means checking timers and automation, not just the pump switch.
Hayward says to allow at least 15 minutes for HydraPure lamps to cool, and warns that handling a hot lamp can cause serious burns. Jandy says to allow adequate time for the quartz tubes to cool.
Open the air relief valve on the filter. Pentair’s BioShield commercial guide says to remove both static and dynamic water pressure from the UV reactor before any maintenance task.
If the unit sits below the pool’s water level, Jandy says all bypass valves must be closed. Otherwise pool water keeps draining through the open unit. Pentair says to close the bypass valves so no more water enters the UV body over the winter.
Pull the drain plug and let every drop out. Each brand’s drain point is different, so follow the brand walkthroughs below.
Wearing gloves, pull the lamps and quartz sleeves, clean any scale, dry them, and store them indoors where they cannot freeze or get knocked over.
Hayward and Pentair both warn that purging the system with compressed air can cause components to explode, with risk of severe injury or death. Use only a low-pressure (below 5 PSI), high-volume blower when air purging the pump, filter, or piping.
Brand-by-Brand Quick Reference
The overall goal is the same for every brand: no power, no pressure, no water, no glass left outside. The details differ. Here is the short version before the full walkthroughs.
- HydraPure: Turn the winterizing O-ring plug near the bottom counter-clockwise. Expect a rush of water. Let it drain 1 to 2 minutes, then reinstall the plug hand tight. Do not lose the plug O-ring.
- HydroRite: Drain all water from the vessel and the venturi. Use a wet-dry vacuum if needed. Store the sleeve, lamp, and connectors so they cannot break or corrode.
- X Series AOP: Close bypass valves if mounted below water level. Open the enclosure door. Remove the 1″ NPT drain plug to drain the remaining water.
- X Series Offline AOP: Remove the Injector Tube Adapter from the Injector under the water inlet. Let all water drain before reinstalling it. Disconnect the ozone check valve tubing from the ozone output barb.
- BioShield: Shut down below 40°F. Close bypass valves, drain via the drain plug, then remove the UV and pour out the water left in the body through an open port.
- Vertical installs: Skipping the pour-out step leaves the quartz sleeve sitting in about 1.25″ of water. When it freezes, the sleeve breaks, and Pentair says that is not covered under warranty.
Hayward HydraPure and HydroRite Walkthrough
Hayward builds the drain into the HydraPure, so the water side of the job is fast. The care goes into the lamp and quartz tube.
Draining the HydraPure
- Turn off all power to the HydraPure and all other pool equipment. Make sure the pump will not re-activate.
- Find the winterizing O-ring drain plug near the bottom of the unit. Turn it counter-clockwise to remove it.
- Expect an initial rush of water. Let the unit drain completely. Hayward says this takes 1 to 2 minutes.
- Reinstall the plug hand tight only. Do not lose the plug O-ring.
Removing the HydraPure lamps and quartz tube
Hayward’s quartz-tube maintenance steps show how the glass comes out:
- With power off, allow at least 15 minutes for the lamps to cool.
- Remove the four screws that secure the lid cover. Use the strain relief to let the cover hang to the side.
- Remove the screw on the electrical enclosure cover and set the cover aside.
- Wearing protective rubber gloves and safety eyewear, disconnect the lamps from the ballast by pressing the release tabs and gently pulling apart. Do not touch the glass part of the lamps.
- Remove the spring clip and carefully lift the lamp assembly from the quartz tube. Do not pull on the lamp wires.
- Turn the round sealing nut counter-clockwise to remove it. Remove the compression washer. Do not lose the black gasket.
- Inspect the quartz tube for cracks or chips. Replace it if you find any.
Hayward’s instructions say not to use any other O-ring for sealing the quartz tube, and never to use any type of lube or sealing agent on it. Doing so can cause a leak and damage the UV unit.
HydroRite notes
The HydroRite needs a longer cool-down than the HydraPure. Hayward’s HydroRite manual says to wait at least 30 minutes after disconnecting power before removing the lamp. Never remove the vessel cap without first unplugging the controller. The cap comes off by removing four mounting screws. Unscrew the UV sensor cable from the center of the vessel top. Then grip the lamp connector, rotate it counter-clockwise about 1/8 turn to unlock, and pull the lamp straight up out of the quartz sleeve. Use the supplied gloves or a clean cotton cloth.
Hayward’s HydroRite winterizing note says to drain all water from the vessel and the venturi, using a wet-dry vacuum if necessary. Then store the sleeve, lamp, and all connectors where they will not break or corrode over winter. When you put the cap back on in spring, do not over-tighten the screws, because the cover can crack.
About the lamp-life reset
The HydraPure has a lamp-life counter. Hayward says to press and hold the OZONE BULB LIFE (or UV BULB LIFE) button for at least 15 seconds to reset it. That reset is for after you install new lamps and restore power. If you are putting the same lamps back in next spring, do not reset the counter, or you lose track of their real hours.
Jandy X Series AOP Walkthrough
Jandy’s X Series AOP adds an ozone side to the job. You have to drain the reactor and also deal with the ozone tubing.
Shutting down
Jandy gives this shutdown sequence for servicing or storage:
- Shut off power at the breaker.
- Shut off water to the unit.
- Open the door. Use a flat-blade screwdriver to turn the door latches counter-clockwise.
- If you are storing the unit, disconnect all electrical, plumbing, and mounting connections.
For any extended shutdown, Jandy also says to disconnect the check valve assembly tubing from the ozone output barb.
Draining the X Series AOP
- If the unit is mounted below the water level, close all bypass valves first. Otherwise extra water keeps draining through the unit.
- Open the enclosure door.
- Find the 1″ NPT drain plug and remove it to drain the remaining water.
- Replace the plug once water stops coming out of the UV reactor.
Draining the X Series Offline AOP
The Offline model drains differently. Close the isolation valves if it is mounted below water level. Then remove the Injector Tube Adapter from the Injector, which sits under the water inlet. Let all the water drain before reinstalling the adapter.
Heads up when you pull the lamp on the Offline unit: Jandy notes that any water left in the unit, or in the plumbing above it, will drain when the UV lamp retainer is removed. Have a towel ready.
Getting the lamps out
Find the UV lamp access panel on top of the unit. Remove its four screws with a Phillips screwdriver and lift the panel off. Let the quartz tubes cool before going further. Remove the sealing O-ring from the top of the quartz tube and set it somewhere safe. Jandy’s Offline AOP needs 13 inches of clearance above the unit to service the lamp and quartz tube. The standard X Series AOP calls for 2 feet of clearance above for maintenance.
Jandy recommends replacing the ozone check valve assembly every year, because high ozone levels and sunlight wear out the tubing. If yours has turned yellow-brown or brittle, closing is a natural time to order a new one so it is ready for spring.
Pentair BioShield Walkthrough
Pentair’s BioShield guidance has one step that catches people out: the pour-out step on vertical installs.
Winterizing in place
- Close the bypass valves so water bypasses the UV and no more water enters the body over winter.
- Drain the UV through the drain plug.
- Remove the UV and pour out the remaining water through one of the open ports.
- Reinstall the UV.
Pentair warns that skipping step 3 on a vertical installation leaves the quartz sleeve sitting in about 1.25″ of water. When that water freezes, it breaks the quartz sleeve, and the damage is not covered under warranty. Pulling the drain plug alone is not enough.
Full disassembly and indoor storage
Pentair also gives a full-storage method:
- Drain all water from the UV system.
- Disassemble the entire unit. Carefully clean the outside and inside of the UV body and parts.
- Once clean and dry, store the UV vessel and power supply in a dry place for winter.
- Return the system to service when temperatures are consistently 40°F or above. Replace the quartz sleeve gasket and do a leak test before running it.
Getting the quartz sleeve out
On residential BioShield units, disconnect power to the UV and pump at the breaker and relieve any leftover pressure. Unthread the black retaining nut and gently remove the quartz sleeve assembly and lamp. Pentair’s residential cleaning steps note they are for above-water-level installations only.
On BioShield commercial units, use the white retaining nut tool that came with the system to unthread the quartz sleeve retaining nut. Wear clean cotton or silicone gloves and slide the sleeve out gently. Pentair says do not use pliers or any tool that could break the sleeve.
Cleaning and Storing Quartz Sleeves and Lamps
Closing is the best time to clean the sleeves, because they are already out. Scale on a sleeve blocks UV light, so a clean sleeve means better sanitizing next season.
Handling the glass
Never touch the lamp glass with bare hands. Hayward says oils from your hands create hot spots during operation and shorten lamp life. Pentair adds that skin oils absorb ultraviolet light and reduce UV intensity. Wear cotton or silicone gloves and hold lamps by the ends only. If you do leave fingerprints, Hayward says to wipe them off with rubbing alcohol.
Cleaning scale off the sleeves
- Mix: Jandy and Pentair both give a ratio of four parts water to one part muriatic acid (4:1). Pentair also allows plain vinegar for calcium deposits. Jandy says a household tub and shower lime remover works for lime or hard-water deposits.
- Always add acid to water: Pentair says always introduce acid to the water, never water to the acid.
- Protect yourself: Pentair says always wear rubber gloves, safety glasses, and an N-95 dust mask when handling muriatic acid. It is corrosive and can burn skin.
- Rinse fully: Pentair says to remove all vinegar or acid from the quartz sleeve assembly before reassembling.
- Dry and inspect: Jandy says to wash and wipe dry, inspect for cracks, and replace the tube if any are found. Make sure the inside is dry before the lamp goes back in.
Jandy also offers an in-place cleaning option for the X Series AOP. You pour the 4:1 solution into the winterizing port so it flows from bottom to top, filling to the top of the quartz tubes.
Storing for winter
Store lamps, sleeves, and connectors indoors, dry, and somewhere they cannot be knocked over. Hayward’s goal is simple: store them in a way that prevents breakage or corrosion over the winter.
- ☐ Before handling: Gloves on, power off, lamps cool.
- ☐ Cleaning: Scale removed with 4:1 water-to-acid or vinegar, acid added to water.
- ☐ Rinse: All acid or vinegar washed off.
- ☐ Inspect: No cracks or chips; cracked sleeves replaced.
- ☐ Dry: Sleeve fully dry inside and out.
- ☐ Store: Lamps, sleeves, connectors, and small seals indoors in a dry spot.
- ☐ Parts list: Note any gaskets, O-rings, or check valves to order before spring.
Mistakes That Crack Glass and Void Warranties
Most UV and AOP freeze damage comes from a handful of repeat mistakes. Each one is avoidable.
- Leaving water in the vessel. Ice inside the vessel can break the sleeve, the lamp, or the vessel. All three brands exclude freeze damage from warranty.
- Trusting the drain plug on a vertical BioShield. About 1.25″ of water stays behind around the sleeve unless you remove the UV and pour it out.
- Opening a below-grade unit without closing valves. Jandy warns that pool water will keep draining into the open unit if the bypass valves are left open.
- Purging with a compressor. Compressed air can make components explode. Use a blower under 5 PSI.
- Putting the wrong antifreeze in the system. Hayward and Pentair say to use only propylene glycol in a pool system; other antifreezes are toxic and can damage plastic parts. Pool antifreeze is for underground plumbing. Our source guidance says not to use it in a pump, filter, heater, or chlorinator. Drain those instead, and treat your UV or AOP vessel the same way.
- Touching lamps with bare hands. Skin oils cause hot spots and shorten lamp life.
- Lubing the HydraPure quartz seal. Hayward says never use any lube or sealing agent on the quartz tube seal.
- Over-tightening plastic caps. Hayward warns the HydroRite cover can crack if the screws are over-tightened. Drain plugs on the HydraPure go back in hand tight only.
Do not stop at the UV unit, either. Hayward and Pentair filter manuals say allowing the filter or pump to freeze will damage it and void the warranty. Hayward’s cartridge filter guide says to leave the filter drain plug out all winter to avoid cracking the filter body.

Brushing, skimming, and clearing leaves off the cover all run off one pole. The ProTuff telescopic pole locks firmly so it does not slip mid-stroke, and it is backed by the 490 Promise.
Status Lights and Service Intervals to Check Before Closing
Before you shut the power off, look at the status lights. They tell you what parts to order over the winter, so you are not waiting on them at opening.
Hayward HydraPure lights
- Flashing red/green UV or OZONE BULB LIFE: The bulb is nearing the end of its life and will need replacing soon.
- Red flashing: The UV bulb is no longer sanitizing, or the ozone bulb is no longer making ozone. Replace it.
- Solid red: The lamp is not powered on. Check the bulbs and ballast connections before replacing anything.
- Hours left: Press and release the UV or Ozone reset button for 1 second. The LED turns off, then flashes yellow once for each 1,000 hours left. Nine flashes means 9,000 hours remaining.
Jandy X Series AOP lights
- Normal: Power green, UV-C purple, Ozone blue.
- Service due: UV-C or Ozone turns yellow. Order new lamps or ozone modules.
- Service overdue: UV-C or Ozone blinks red.
- Power red with UV-C and Ozone off: A flow problem or the UV access door is not properly closed.
- All lights off: No power to the system. Check the breaker.
| Item | Hayward HydraPure | Jandy X Series AOP | Pentair BioShield |
|---|---|---|---|
| Quartz sleeve cleaning | Every 12 months | Remove every 6 months and clean if needed | Inspect and clean twice a year (at least once a year) |
| UV lamp replacement | When the bulb-life light says so | After 16,000 hours | After 12,000 hours of cumulative use |
| Ozone part replacement | When the ozone bulb-life light says so | Ozone modules typically after 12,000 hours; check valve assembly and ozone gas line yearly | Not applicable (UV only) |
| Drain point | Winterizing O-ring plug near the bottom | 1″ NPT drain plug (Offline: Injector Tube Adapter) | Drain plug, plus pour-out through an open port |
| Freeze damage covered? | No | No (broken quartz tube not covered) | No |
Pentair’s commercial BioShield schedule adds a few more checks: a daily visual look for leaks, a monthly check for damage or corrosion, and a yearly inspection and cleaning of the vessel interior. When BioShield lamps are replaced, Pentair says to calibrate the UV intensity sensor and replace the retaining nut O-ring or gasket. Pentair also warns not to let the system exceed 50 PSI.
Frequently Asked Questions
Can I leave the lamp and quartz sleeve inside the unit over winter if I drain the water?
It is safer to take them out. Hayward says to store the sleeve, lamp, and connectors so they will not break or corrode over winter, and Pentair’s full-storage method moves the vessel and power supply to a dry place. Glass left outside in a cold vessel is exposed to any water you missed.
How long does it take to drain a Hayward HydraPure?
Hayward says the HydraPure drains completely in about 1 to 2 minutes once you remove the winterizing O-ring plug near the bottom. Expect a rush of water at first. Reinstall the plug hand tight only, and do not lose its O-ring.
Why did my vertical Pentair BioShield sleeve break after I pulled the drain plug?
On vertical installs, the drain plug leaves about 1.25 inches of water around the base of the quartz sleeve. Pentair says you must remove the UV and pour that water out through an open port. If it freezes, the sleeve breaks and the damage is not covered under warranty.
Do I need to close valves before draining my Jandy AOP?
Yes, if the unit sits below the pool’s water level. Jandy says all bypass valves must be closed first. If they are open, pool water will keep draining through the unit when you pull the 1-inch NPT drain plug or remove a quartz tube.
When should I shut down my UV system for the winter?
Pentair recommends shutting down BioShield units when the temperature consistently falls below 40°F (4°C). General pool closing guidance says to wait until the water is 60°F or lower, but to start well before any danger of freeze so the equipment can fully drain and dry.
What should I use to clean scale off a quartz sleeve?
Jandy and Pentair both give a mix of four parts water to one part muriatic acid. Pentair also allows vinegar. Always add acid to water, never the reverse, and wear rubber gloves, safety glasses, and an N-95 mask. Rinse off all acid and dry the sleeve completely before storing it.
Can I blow out my lines with an air compressor?
No. Hayward and Pentair both warn that purging with compressed air can make components explode, with risk of severe injury or death. Use only a low-pressure, high-volume blower running below 5 PSI when purging the pump, filter, or plumbing lines.