Freeze protection is the setting that turns your pump on by itself when the air gets close to freezing. It works well when it is set up right, and it fails quietly when it is not. The right pool freeze protection settings depend on which controller you own, because Hayward, Pentair and Jandy each use different temperatures, pump speeds and valve timing.
This guide walks through what each manufacturer’s manual says, model family by model family, so you can check your own system before the first cold night.
You Could Win Free ProTuff Gear β Every Month
No Spam. Unsub anytime. Remain subscribed, remain eligible every month.
How Freeze Protection Works
All three controller families work from the air temperature sensor, not the water sensor. The Hayward OmniLogic manual describes it this way: “If freeze protection is enabled AND the air temperature falls below the freeze threshold, the OmniLogic will turn on the filter pump to circulate the water.”
Moving water is the whole idea. The controller does not heat anything in freeze mode. It keeps water flowing through the pump, filter and pipes until the air warms up again.
On Jandy AquaLink RS systems, the manual says “the main filter pump is freeze-protected as a default.” The AquaLink PDA manual goes one step further and adds that it “cannot be removed from freeze protection.” You choose which other equipment joins it.
The Jandy AquaLink manual is direct about the limit: “Freeze protection is intended to protect equipment and plumbing for short periods of freezing only… Freeze protection does not guarantee that equipment will not be damaged by extended periods of freezing temperatures or power outages. In these conditions, the pool and spa should be shut down completely (e.g. drained of water and closed for the winter) until warmer weather exists.” No power means no pump, so plan for outages.
How to Program It: The Order That Matters
The menu names differ by controller, so use your own manual for the exact screens. The order below is the same on all three brands, and it matters because each step depends on the one before it.
Freeze protection cannot start without a working air sensor. Check that the controller shows an air temperature that matches a thermometer you trust, and that the sensor sits in the shade. A sensor in direct sunlight reads warm, which delays freeze mode.
Decide which circuits need moving water: the filter pump, the spa, a cleaner or booster pump line, a water feature. On Hayward systems the manual notes the threshold you set “will be used for all outputs that have freeze protection enabled.”
Hayward and Jandy let you choose the temperature. Some Pentair controllers use a fixed one. The table in the next section shows what each manual gives.
Pick the speed the pump runs at in freeze mode. Each brand handles this differently, and Pentair IntelliCenter has a rule about pump addresses that is easy to miss. See the freeze speed section below.
If both the pool and the spa are freeze protected, the controller swaps the valves back and forth on a timer. Make sure the setting that pauses the pump while the valves turn is switched on.
Jandy OneTouch, AquaLink Touch and PDA screens show “FREEZE PROTECT” or “FREEZE PROTECTION ACTIVATED” when freeze mode is running. Knowing the message for your controller lets you confirm it at a glance on a cold night.
Temperature Thresholds by Controller
These are the activation temperatures the manufacturer manuals give. Each row applies only to the controller family named in it.
| Controller family | Turns on at | Adjustable? | Turns off at |
|---|---|---|---|
| Hayward OmniLogic, OmniPL, OmniHub | 38Β°F (3Β°C) default | Yes, 33Β°F to 42Β°F (1Β°C to 6Β°C) | Not stated in our sources |
| Hayward Pro Logic, Aqua Plus, E-Command 4, OnCommand | 38Β°F (3Β°C) default | Yes, 33Β°F to 42Β°F (1Β°C to 6Β°C) | Not stated in our sources |
| Pentair EasyTouch, IntelliTouch | Two values in the manual: “below 35Β° F” in the circuit function text, and “below 36Β° F (2Β°C)” in the EasyTouch status display text | No adjustment given in our sources | Not stated in our sources |
| Pentair SunTouch | 36Β°F or lower in the general text; the Advanced Menu reads “On at 35Β° F, off at 38Β° F” | No adjustment given in our sources | 38Β°F per the Advanced Menu text |
| Pentair IntelliCenter | Not stated in our sources. Check your IntelliCenter manual. | See manual | See manual |
| Jandy AquaLink RS (OneTouch, All Button, Touch) and AquaLink PDA | 38Β°F (3Β°C) default | Yes, 34Β°F to 42Β°F (1Β°C to 6Β°C) | 2Β°F above the temperature you set |
The Pentair documents disagree with themselves by one degree. We show both values rather than pick one. If one degree matters for your equipment, watch the controller on a cold night and note when it starts.
The Jandy turn-off rule moves with your setting. Raise the activation temperature and the turn-off temperature rises with it, so the pump runs for more of the night. That is the trade you make for an earlier start.
Freeze Speeds for Variable Speed Pumps
A variable speed pump needs a speed for freeze mode. Here is how each brand’s controller decides it.
- OmniLogic, OmniPL, OmniHub: The manual asks “Freeze Protect Speed? This is the speed of the pump while freeze protection is active. Select the desired pump speed %.” A two-speed pump gets a choice of 50% or 100%.
- Pro Logic: For variable speed pumps the manual says “Select the desired speed (from Filter Lowest to Filter Highest speed).” A two-speed pump runs on High by default, with Low as the other choice.
- AquaRite S3 (standalone): With recirculation freeze protection on, “the pump will run at the speed programmed in the ‘Filter Pump’ section.”
- IntelliCenter, pump address 1: “For address 1 (typically the filter pump), it is not necessary to turn freeze protection off to set the freeze speed (this is different from EasyTouch/IntelliTouch operation).”
- IntelliCenter, pump addresses 2 to 16: “It is necessary to turn freeze protection off to set the freeze speed.” Turn it back on when you finish.
- IntelliCenter, shared pumps: “When a variable speed pump is connected to multiple circuits and there are different speed settings on each circuit, the pump will default to the highest speed.” With a mix of RPM and GPM settings, “the pump prioritizes the GPM settings over the RPM settings.”
- AquaLink RS with a variable speed pump: “In the Freeze Protect mode the pump will turn ON and be set to at least the freeze protect speed. If the Filter Pump speed is higher than the Freeze protect speed, then the pump will run at the filtration speed.”
- Freeze-protected auxiliaries: “If speeds have been assigned to auxiliaries and if those auxiliaries are freeze protected, the pump will be set to the highest of the speeds.”
None of the manuals in our sources gives one correct freeze speed for every pool. The speed has to move water through every exposed pipe on your pad, so a pool with long pipe runs or raised equipment needs more than a compact one. Start from your pump manual and confirm you see flow at the returns.
Pool and Spa Valve Cycling
On a pool and spa combination, the pump can only push water through one side at a time. So the controller swaps the valves on a timer to keep both sides moving. This is normal, and it only happens when both the pool and the spa are set for freeze protection.
| Controller family | Valves swap every | Pump pause while valves turn |
|---|---|---|
| Hayward OmniLogic, OmniPL | 30 minutes | 35 seconds when “Filter Pump Off for Valve Change” is set to Yes |
| Hayward Pro Logic | 30 minutes | 35 seconds when “Filter Off Valve Change” is enabled (enabled by default) |
| Pentair EasyTouch, IntelliTouch | 15 minutes | 30 seconds when “Delays For Valves” is on |
| Pentair SunTouch | 15 minutes | Not stated in our sources |
| Pentair IntelliCenter | Adjustable “Freeze Cycle Time”, 5 to 60 minutes, default 5 minutes | 30 seconds when Valve Delay is ON |
| Jandy AquaLink RS, AquaLink Touch | 30 minutes | 35 seconds, the time the valves take to rotate |
The pump pause protects the equipment. The Jandy AquaLink Touch manual explains that “the filter pump turns off while valves rotate between pool and spa to prevent damage to the pool equipment.” One Hayward exception is worth knowing: on Pro Logic, “the pump will NOT shut off when a heater is in Heater Cooldown mode.”
What Freeze Mode Does Not Do
Freeze mode moves water. Two things owners often expect from it do not happen.
Your salt system does not make chlorine. Hayward’s OmniLogic and Pro Logic manuals both say “the chlorinator will not operate if freeze protection is the only reason the pump is running.” Pentair says the same for its cell on EasyTouch and IntelliTouch: “While in ‘Freeze Protection’ mode, IntelliChlor will not operate or produce chlorine during the time that the filter pump is operating.” So a pool that runs mostly on freeze protection through a cold week is not being sanitized by the salt cell. Test the water and adjust by hand.
Your pump’s own sensor is not a backup. Many variable speed pumps have a built-in cold-weather mode. It is there to protect the pump drive, and it steps aside once the pump is wired to a controller.
Pentair’s IntelliFlo manuals say: “This feature is for protection of the pump. Do not depend on the Thermal Mode feature for freeze protection of the pool… The pump’s internal thermal protection is disabled when connected to an automation system.” Hayward’s variable speed pump manuals (TriStar VS, MaxFlo VS, Super Pump VS) say the same about their version: “Low temperature operation is not active when the pump is being remotely controlled. Low temperature operation is NOT intended to protect the pump, system plumbing, or pool from freezing.”
On Pentair systems, the controller takes over that job only when you tell it to. The pump manual says thermal protection “is provided by selecting YES at the ON WITH FREEZE portion of the circuit function menu in the IntelliTouch Control System.” If that is set to No, nothing is watching.
Mistakes the Manuals Warn About
Using the spa on a freezing night. The Jandy AquaLink manual carries this caution: “Activating the spa during freezing conditions will override freeze protection. This means that if you are using your spa when freezing conditions exist, freeze protection will not circulate water to non-spa related equipment that you may have freeze protected (e.g. pool cleaner, booster pump.) Under these circumstances, the potential for equipment damage may exist.” Pentair IntelliCenter has a “Spa Freeze Override Time” setting, adjustable from 0 to 240 minutes, that controls how long the spa may run this way.
Overriding freeze protection and forgetting it. Hayward Omni systems let you override freeze protection for 60 minutes with the Freeze Prot. button. The manual adds: “Ensure that equipment is protected from a freeze condition before overriding this feature.” Touch the button again to resume normal freeze protection.
Disabling or ignoring the air sensor. Hayward’s AquaRite S3 manual warns that “if freeze protection is currently enabled and then the air sensor is disabled, freeze protection will no longer activate.” Jandy’s manual says that when “AIR SENSOR OPEN is displayed, freeze protection will not operate correctly.” On Pentair EasyTouch, an air sensor that is not connected shows as “Air Err” on the main screen. Treat any air sensor message as urgent in cold weather.
Trusting Wi-Fi freeze protection without a backup. Pentair IntelliConnect has no local air sensor in the loop. It “uses data from an internet based weather service and updates hourly.” Pentair’s warning: “If your wireless connection, internet or the weather service website is not working the IntelliConnect freeze protection feature will not function. Additional steps will be required to avoid property damage from freezing temperatures.”
Letting leaves choke the flow. Freeze protection only helps if water actually moves. A skimmer basket or pump basket packed with fall leaves cuts the flow. Hayward OmniLogic and Pro Logic controllers with a flow switch and flow monitoring turned on will shut the pump down if they detect no flow. Empty the baskets and skim the surface before a cold front, not after.

A quick skim before a cold night keeps leaves from reaching the skimmer and pump baskets, so the pump can keep water moving. The ProTuff Pool Net is covered by our 490 Promise.
- β Air sensor: the reading matches a real thermometer, and the sensor is in the shade.
- β Freeze protection: turned on for every circuit with exposed plumbing, including the spa if you have one.
- β Threshold: set to the value you chose from the table above.
- β Freeze speed: set, and you have seen flow at the returns at that speed.
- β Valve pause: the pump-off setting for valve changes is enabled.
- β Baskets and filter: clean, so flow is not restricted.
- β Outage plan: you know what you will do if the power fails during a freeze.
Freeze protection is a controller job, not a pump job. Once a variable speed pump is wired to automation, the controller’s air sensor and its settings are the only things standing between a cold night and frozen plumbing.
Frequently Asked Questions
Why do my pool valves keep turning back and forth when it is cold?
That is the controller doing its job. When both the pool and the spa are freeze protected, it swaps the valves on a timer so water moves through both sides. The interval for your controller is in the valve cycling table above, and the short pump stop during each swap is normal.
Will freeze protection save my equipment in a power outage?
No. Freeze protection needs power to run the pump, and Jandy’s manual says plainly that it does not guarantee against damage from power outages or extended freezing. In those conditions the manual says the pool and spa should be shut down completely, which means drained and closed until warmer weather.
Can I set the freeze speed on a second Pentair pump the same way as the filter pump?
Not on IntelliCenter. The filter pump at address 1 lets you set the freeze speed with freeze protection left on. For pumps at addresses 2 to 16, the manual says you must turn freeze protection off to set the freeze speed, so remember to turn it back on afterward.
Should I raise my freeze protection temperature to be safe?
On Hayward and Jandy controllers you can, within the range shown in the thresholds table. A higher setting starts the pump earlier and keeps it running longer, which gives more margin if your air sensor reads a little warm or your equipment pad sits in a cold, windy spot.
How do I know freeze protection is actually running?
Look at the controller on a cold night. Jandy screens show a freeze protect message, and Hayward and Pentair controllers show their own freeze indicator. If the air is below your threshold and you see no indicator and no pump running, check for an air sensor error first.
You Could Win Free ProTuff Gear β Every Month
No Spam. Unsub anytime. Remain subscribed, remain eligible every month.