Opens in a new tab
Swimming pool ladder
How-to Guides

How to Winterize Your Inground Pool Pump: Drain Plugs, O-Rings, and the No-Plastic-Wrap Rule for Hayward, Pentair, and Jandy

ProTuff Team

ProTuff Team
October 1, 2026 · Equipment Use

Water expands by about 9% when it freezes. Trapped inside a pump strainer pot or volute, that expansion creates enough force to split plastic housings that would otherwise last for years — and freeze damage is excluded from Hayward, Pentair, and Jandy warranties.

The good news: learning how to winterize a pool pump correctly takes one afternoon and a handful of cheap supplies. This guide walks through the exact sequence, the brand-specific drain plugs and lids, the right lubricant for your O-rings, and the one mistake that quietly kills more pump motors than any freeze: wrapping them in plastic.

$1,000 Monthly “Freebie Friday” Drawing

You Could Win Free ProTuff Gear — Every Month

Pool Care GuideMaintenance Checklists45 Pool Games eBookWeekly Tips & Deals

No Spam. Unsub anytime. Remain subscribed, remain eligible every month.

When to Winterize Your Pool Pump

Pump winterization happens once a year, at the end of the swim season. The trigger is water temperature, not the calendar. Wait until your pool water stays consistently below 60°F to 65°F (15°C–18°C) before you close.

Closing too early is a common and expensive mistake. Warm water burns through sanitizer and winter algaecide fast, so a pool closed while the water is still warm can open in spring as a green swamp. Water below 60°F, on the other hand, keeps algae growth in check under the cover.

Watch for these signs that it is time to act now:

  • Water temperature dropping below 60°F–65°F. This is your primary signal.
  • Frost alerts or forecast lows at 32°F (0°C). Water expands about 9% as it freezes, so an un-winterized pump or exposed plumbing with still water in it can crack during a hard freeze.
  • Heavy autumn leaf drop. Rotting leaves consume chlorine and clog skimmers, which can starve the pump.

Before you touch the equipment pad, balance the water (pH 7.2–7.8, total alkalinity 80–120 ppm, calcium hardness 200–400 ppm), add your winter chemicals — non-chlorine winter shock, stain and scale preventer, and a non-copper winter algaecide — and run the pump for 4 to 12 hours so everything circulates through the plumbing. Then lower the water level: 4 to 6 inches below the skimmer for solid winter covers, or 6 to 12 inches below the skimmer (no more than 18 inches below the deck) for mesh safety covers.

⚠ Never Drain an Inground Pool Completely

Lowering the water level for winter is correct. Emptying the pool is not. An empty concrete, vinyl, or fiberglass pool is exposed to groundwater pressure that can pop the shell out of the ground, tear a liner, or crack plaster.

Tools and Supplies You Need

You do not need specialty equipment, but you do need the right versions of a few common items. The wrong lubricant or the wrong antifreeze causes damage you will not discover until spring.

Tool / SupplyWhat It’s ForCaution
Silicone or Teflon pool lubricant (e.g., Magic Lube, Boss 820, Jack’s 327)Coating pump lid O-rings, drain plug O-rings, union O-rings, and filter tank O-ringsNever use petroleum jelly (Vaseline) or WD-40 — petroleum degrades EPDM rubber O-rings
Teflon thread tapeWrapping male-threaded drain plugs that have no rubber O-ring (3 wraps, clockwise)Prevents thread galling and drips at spring startup
Low-pressure, high-volume air blower (pool line blower or wet/dry shop vac)Purging water from plumbing linesBelow 5 PSI — manufacturers warn that compressed air can make components explode
Non-toxic propylene glycol (pool/RV antifreeze)Protecting underground plumbing and skimmer lines after blowoutNever automotive antifreeze; never pour antifreeze into pumps, filters, heaters, or chlorinators
Wrenches and sockets (3/4″ socket; 3/8″ and 9/16″ open-end wrenches)Filter drain plugs, clamp bolts, and pump disassemblyUse properly fitting sizes to avoid stripping hardware
Winterizing plugs (#9–#11 expansion plugs) and skimmer plugs/GizzmosSealing return lines, suction lines, and skimmersProtects skimmer housings from ice expansion

While you are at the pool, give it a final pass before the cover goes on. Leaves and debris left under a cover consume chlorine all winter.

ProTuff Pool Net leaf rake

Clear the leaves before you close
Pool Net

Fall leaf drop is one of the signs it’s time to close — and rotting leaves under a cover eat your winter chemicals. The ProTuff leaf rake pulls debris out fast before the cover goes on, and it’s backed by the 490 Promise.

View Pool Net · $49.97

Safety First: Power Off and 0 PSI

Two things must happen before you loosen a single plug, lid, or clamp: the power must be off, and the system pressure must be zero.

1
Shut off power at the breaker

Turn off electrical power to the pump motor, heater, salt system, and automation panel at the main house circuit breaker and the equipment disconnect switch. Pressing Stop on the pump’s keypad is not enough.

2
Relieve filter pressure to 0 PSI

Open the manual air relief (MAR) valve on top of the filter tank. Wait until the pressure gauge reads 0 PSI and water stops spraying before you loosen any clamp band, pump lid, or drain plug.

🚫 Pressurized Tanks Can Separate Violently

Filter tanks and pumps are typically rated for a maximum working pressure of 50 PSI. Opening a pressurized system — or starting a pump against closed valves or installed winter plugs — can blow off lids and clamp bands, causing serious property damage, injury, or death. Always confirm 0 PSI first.

The Correct Winterizing Sequence (and Why Order Matters)

Doing the right steps in the wrong order is almost as bad as skipping them. Here is the sequence that protects every component on the pad.

1
Disconnect power and relieve pressure to 0 PSI

Breaker off, filter air relief valve open, gauge at zero.

2
Lower the water and purge the plumbing lines

Use a low-pressure blower (under 5 PSI) to push water out of the suction and return lines.

3
Plug skimmers, return jets, and main drain lines

Seal each line with expansion plugs or skimmer plugs so water can’t flow back in.

4
Gravity-drain all equipment

Remove the drain plugs from the pump, filter, heater, and chlorinator and let every housing empty completely.

5
Clean, inspect, and lubricate O-rings

Wipe each O-ring and its groove clean, check for cracks or flattening, and coat with silicone or Teflon lube.

6
Store plugs in the strainer basket and protect the motor

Drop the drain plugs into the pump basket, set the lid on loosely, and protect the motor with a ventilated shelter — never plastic wrap.

Why the order matters: if you pull the equipment drain plugs before blowing out the lines, the air escapes through the open equipment ports instead of pushing water out of the underground pipes. That leaves water in the return and suction lines, where it can freeze and burst PVC. And blowing air into the system before relieving filter pressure risks explosive lid separation.

Brand-by-Brand Pump Procedures

Every major inground pump has two drain plugs: one at the base of the front strainer pot, and a second farther back on the lower volute (impeller housing). What differs by brand is the plug style, the lid mechanism, and a few part numbers worth knowing if you need replacements.

HAYWARD
Two 1/4″ NPT plugs; Tri-Lock cam lid on TriStar, hand knobs on Super Pump

  • Models covered: TriStar VS (SP3200VSP / SP3206VSP), Super Pump VS (SP2603VSP), MaxFlo VS (SP2303VSP), Super Pump, and Super II (SP3000 series).
  • Drain plugs: Two wing-nut or hex-head 1/4″ NPT plugs — one at the front base of the strainer pot, one on the lower volute. Replacement plugs with O-rings include SPX4000FG and SPX1700FG (newer O-ring design).
  • Lid: Rotate the Tri-Lock cam lid counter-clockwise (TriStar) or loosen the swing-away hand knobs (Super Pump).
  • Steps: Breaker off and filter at 0 PSI. Unscrew both drain plugs and let the housing gravity-drain. Remove the strainer basket and clear debris. Inspect the lid O-ring for cracks or flattening, wipe it and the groove clean, and apply a liberal coat of silicone lubricant such as Magic Lube.
  • Storage: Place both drain plugs inside the strainer basket and reinstall the lid loosely.
  • Unions: If your pump has quick-disconnect unions (e.g., SPX3200UNKIT), you can loosen them and carry the pump indoors.
PENTAIR
Two hand-turned thumbscrew plugs; Cam & Ramp lid on most models

  • Models covered: IntelliFlo3 VSF, IntelliFlo VS/VSF, WhisperFlo / WhisperFloXF, SuperFlo / SuperFlo VST, and Max-E-Pro.
  • Drain plugs: Two 1/4″ NPT thumbscrew plugs at the bottom of the strainer pot and lower volute — no tools needed. Replacement plugs include 071131 / 071131Z (almond) and 357161Z (black), with 192115 / 192115Z O-rings.
  • Lid: On IntelliFlo, WhisperFlo, and SuperFlo, turn the Cam & Ramp lid counter-clockwise 1/4 turn to remove. Max-E-Pro uses a Quick-Lock trap cover ring instead.
  • Steps: Press Start/Stop, then turn off the circuit breaker. Relieve filter pressure to 0 PSI. Unscrew both plugs by hand and gravity-drain the housing. Clean and lubricate the lid O-ring and the drain plug O-rings with a silicone lube such as Boss 820 or Lifegard.
  • Storage: Store the plugs inside the pump basket.
  • Automation note: If you are fully closing, disconnect power so freeze protection does not kick on and run an empty pump.
JANDY
Two tool-free plugs with O-rings (R0446000); unions make indoor storage easy

  • Models covered: VS FloPro, ePump, PlusHP, Stealth, and FHP.
  • Drain plugs: Two tool-free drain plugs with O-rings on the front and side base of the pump body. The R0446000 replacement set contains both plugs with matching O-rings.
  • Steps: Shut off the main circuit breaker and open the filter air release valve. Unscrew both plugs and make sure their O-rings stay with them. Jandy manuals say to store the plugs in a safe place until spring — the pump basket works well.
  • Unions: Loosen the two quick-disconnect unions (1.5″, 2″, or 2.5″) on the suction and discharge ports to drain water trapped in the internal piping. Replacement union kits include R0327301.
  • Indoor storage: Jandy manuals recommend having an electrician disconnect the wiring at the junction box so the pump can be carried indoors for winter.
  • O-rings: Inspect the lid seal and union O-rings and apply silicone pool lube before storage.
💡 Pro Tip

Storing the drain plugs inside the strainer basket isn’t just tidy — it guarantees the plugs are sitting right where you need them at spring startup. Lost plugs are one of the most common reasons a spring opening stalls.

O-Rings: Silicone Lube Only, Never Petroleum

Your pump’s lid O-ring, drain plug O-rings, and union O-rings are what keep air out of the system. Winter is when they dry out and crack, so fall is the time to service them.

Here’s the process for each O-ring:

  • Remove the O-ring and wipe both the ring and its seating groove completely clean.
  • Inspect for cracks, flattening, or stretching. Replace any O-ring that shows damage.
  • Apply a liberal coat of 100% silicone-based or Teflon-based pool lubricant.
  • For threaded drain plugs without a rubber O-ring, wrap the threads three times clockwise with Teflon tape instead.
🚫 No Vaseline, No WD-40

Petroleum-based products chemically break down EPDM rubber O-rings, causing them to swell, split, and leak air. Resulting seal failures are not covered under warranty. A replacement O-ring or gasket kit runs about $15–$60 — but an air leak can also starve the pump and damage the seal.

The No-Plastic-Wrap Rule for Pump Motors

It feels like the protective thing to do: wrap the motor in plastic or a trash bag to keep the weather out. It is exactly the wrong move.

Plastic wrap, trash bags, airtight tarps, and shrink wrap trap humidity and ground condensation inside the motor housing. As winter cycles between freezing and thawing, that moisture condenses on the metal parts inside and causes heavy rust between the stator and rotor. By spring the bearings lock up, the motor shaft won’t turn, and the windings or capacitor can burn out on the first start.

Key Takeaway

Never wrap a pump motor in plastic. Hayward, Pentair, and Jandy manuals all warn that it traps condensation that rusts and damages the motor. A motor shop re-bearing typically runs about $100–$175, a replacement motor about $200–$400, and a whole new pump $400 to $1,200 or more.

You have two correct options:

  • Leave it outdoors with ventilation. Leave the motor uncovered, or cover it with a breathable shelter — a wooden lean-to, or an upside-down plastic tub or laundry basket with side cutouts for airflow. This sheds snow and falling branches while air keeps moving.
  • Store it indoors (the best option). If your pump has quick-disconnect unions, turn off power at the breaker, have the wiring disconnected, loosen the unions, and carry the pump to a dry, temperate basement or garage. Indoor storage also protects the capacitor from extreme cold.
⚠ Keep the Pump Away From Pool Chemicals

Don’t store the pump next to your chlorine. Chlorine off-gassing corrodes copper windings and steel bearings — the same damage you were trying to avoid.

Winterizing the Filter and Multiport Valve

The pump is only one part of the pad. A filter left full of water can crack its tank, split the multiport valve body, or crush the grids or cartridges inside. The general rule: drain it, clean the media, and store it dry. Most of these manuals also say to leave the bottom drain plug out all winter so any rain or snowmelt that gets in drains instead of freezing — but check your model, because Pentair’s FNS Plus manual has you store the plug and reinstall it when you reassemble the tank.

HAYWARD
SwimClear cartridge, Pro-Grid DE, and S-Series sand

  • SwimClear cartridge (C2030–C7030; single-element C100S–C200S): Open the top manual air relief valve by turning it counter-clockwise. Remove the 1.5″ bottom drain plug with a 3/4″ socket. Loosen the clamp nut, remove the tank head, and lift out the cartridges. Hose them down, soak in filter cleaner if oily, dry completely, and store indoors. Reassemble the empty tank and leave the drain plug out.
  • Pro-Grid vertical DE (DE2420–DE7220): Open the air relief valve and remove the 1.5″ bottom drain plug. Remove the clamp band and dome, then hose all DE off the grid assembly — never winterize with DE left on the grids. Store the grids indoors or reinstall them clean. Leave the drain plug off.
  • S-Series sand (S180T, S210T, S244T): Unscrew the drain cap at the base of the tank (the internal lateral cap keeps sand in). Press down the valve handle and rotate it to the WINTER/WINTERIZE position, or between any two settings, to relieve the spider gasket.
PENTAIR
Clean & Clear cartridge, FNS Plus DE, and Triton II sand

  • Clean & Clear Plus (CCP240–CCP520): Open the top High Flow manual air relief valve and wait for 0 PSI. Open the bottom drain plug (P/N 190030) and let the tank drain. Loosen the clamp barrel nut with a 7/8″ socket, remove the clamp ring and lid, and lift out the four cartridges. Clean them and store them, with the drain plug, somewhere protected from freezing.
  • Clean & Clear (CC50–CC200): Open the air relief valve and remove the 1.5″ drain plug (P/N 86202000). Unthread the locking ring, remove the single cartridge, clean it, and store it indoors in a dry place.
  • FNS Plus vertical DE (FNSP24–FNSP60): Backwash before closing. Open the air relief valve, remove the 1.5″ bottom drain plug, pull the grid assembly, rinse off all DE, and store the grids and the drain plug where they won’t freeze. Pentair’s manual then has you reassemble the tank and reinstall the drain plug.
  • Triton II sand (TR40, TR60, TR100): Backwash thoroughly, shut off the pump, and open the air bleeder. Remove only the drain plug — the wing-type plug on the TR40 and TR60, or the 1-1/2″ drain cap on the TR100 — not the whole fitting, or sand will escape. The filter drains slowly, so Pentair recommends leaving the plug out. Move the multiport handle to WINTERIZE so the diverter’s rubber seal has no pressure on it.
JANDY
CL/CV and CS cartridge, DEL vertical DE

  • CL/CV (CL340–CL580 / CV340–CV580) and CS (CS100–CS250): Turn off the pump breaker and open the air release valve. Loosen the drain plug at the base of the tank and drain completely. Open the tank — CS models use a locking ring, while CL and CV models use a two-piece clamp ring — then take out the cartridges, clean them, and store indoors. Keep the drain plug somewhere safe and don’t reinstall it until spring.
  • DEL vertical DE (DEL48, DEL60): Open the air release valve. Move the slide valve or multiport handle to an intermediate position between two ports so air can flow through every branch. Remove the bottom drain plug, flush DE off the grids, and store the grid assembly indoors. Keep the drain plug off.

Leaving a multiport valve in the FILTER position all winter keeps constant pressure on the rubber spider gasket. That causes permanent compression or tearing, which leads to water leaking to waste next season — roughly $50–$150 for a gasket repair, or $150–$300 for a new valve.

Blowing Out Lines and Using Pool Antifreeze

In hard-freeze climates, the underground plumbing needs the same protection as the pump. Use a low-pressure, high-volume blower — a pool line blower or a wet/dry shop vac — to push water out of each suction and return line, then seal each line with an expansion plug (#9, #10, or #11) or a skimmer plug.

🚫 Never Exceed 5 PSI

Hayward and Pentair manuals warn never to purge the system with compressed air. It can cause filter lids, tanks, and strainer covers to explode apart, with risk of severe injury or death. The PVC pipe itself isn’t the weak point — it’s the equipment. Use only a high-volume blower below 5 PSI. Tank replacement or deck excavation can run $500–$3,000 or more.

After blowing out and plugging the lines, add non-toxic propylene glycol (pool/RV antifreeze) at a rate of about 1 gallon per 10 feet of plumbing pipe. Keep these rules in mind:

  • Use only propylene glycol labeled for pool or RV use.
  • Never use automotive antifreeze (ethylene glycol). It is highly toxic to people and pets and degrades plastic pool components.
  • Never pour antifreeze directly into the pump, filter, heater, or salt chlorinator. Those components are protected by draining, not antifreeze.

Larger pools mean more lines. A 10,000-gallon pool with a single skimmer line purges quickly, while a 30,000-gallon-plus pool may have multiple skimmers, main drains, in-floor cleaning valves, or booster pumps — each needs to be individually blown out and plugged.

Freeze Protection Modes and the Soft-Close Option

Many automation systems include freeze protection that runs the pump automatically when outdoor air temperatures drop. Moving water is far less likely to freeze than still water.

SystemHow Freeze Protection WorksDisplay Message
Pentair IntelliFlo (built-in Thermal Mode / Anti Freeze)Runs the pump when the sensor inside the pump’s drive drops below its setpoint (40°F default, adjustable 40°F–50°F). It senses drive temperature, not outdoor air — Pentair says it protects the pump only and should not be relied on to protect the pool. It is disabled when the pump is connected to an automation system.“Thermal Mode” / “Anti Freeze” menu
Pentair EasyTouch / IntelliTouch / IntelliCenter automationTurns on circuits assigned to freeze protection when the outdoor air sensor drops below about 35°F–36°F. With pool and spa both assigned, the valves alternate every 15 minutes.EasyTouch: “FRZ”; IntelliCenter: “Freeze Protect Active”
Hayward OmniLogic / OmniPLTurns on the filter pump below the freeze setpoint (38°F default, adjustable 33°F–42°F). With pool and spa configured, the valves alternate every 30 minutes. The chlorinator won’t run if freeze protection is the only reason the pump is on.Freeze indicator / “Freeze Prot.” button on the Features screen
Jandy AquaLinkTurns on equipment assigned to freeze protection (such as the filter pump) when the freeze sensor detects freezing conditions.“FREEZE PROTECT”

In mild climates where hard freezes are rare and water stays warmer, some owners do a “soft close” — keeping the pool open with shorter runtimes and relying on freeze protection during brief cold snaps. In hard-freeze climates, where temperatures stay below freezing for days, a full closing with drained equipment and blown-out lines is required.

⚠ Freeze Protection Needs Electricity

If a winter storm knocks out power during sub-freezing weather, freeze protection stops instantly. Shut off the equipment breakers, open the filter air relief valve to drop pressure to 0 PSI, and pull all equipment drain plugs so the pad gravity-drains before water freezes inside the housings.

On a fully closed pool, remember the flip side: disconnect the power so freeze protection can’t start an empty pump. Running a pump without water damages the mechanical shaft seal, and dry-run damage can void your warranty.

Common Mistakes and What They Cost

Hayward, Pentair, and Jandy all treat freeze damage — cracked volutes, split filter tanks, ruptured heater headers, cracked salt cells — as improper maintenance excluded from their warranties. That means every mistake below comes out of your pocket. Cost ranges are typical estimates and vary by region and equipment.

MistakeConsequenceTypical Cost
Leaving water in the pump / forgetting drain plugsIce cracks the strainer pot or volutePart replacement, up to a new pump ($400 to $1,200+)
Wrapping the motor in plasticTrapped condensation rusts the motor and its bearingsAbout $100–$175 (re-bearing) or $200–$400 (replacement motor)
Petroleum jelly or WD-40 on O-ringsSeals swell, split, and leak airAbout $15–$60 (O-ring/gasket kit)
Automotive antifreeze in the linesToxic to people and pets; can damage plastic componentsVaries — avoid entirely
Purging with compressed air above 5 PSIFilter lids, tanks, or strainer covers can explode apart$500–$3,000+ (tank replacement or excavation), plus injury risk
Trichlor tablets left in the skimmerAcidic water eats pump threaded adapters and shaft seals while the pump is offAbout $150–$300 (adapter/seal) or $1,000–$2,000+ (skimmer replacement)
Leaving the filter full of waterCracked tank, split multiport valve, crushed grids or cartridgesA replacement tank can cost 50–80% of a new filter
Leaving DE on the gridsWet DE dries and cakes into the grid fabric, clogging itAbout $100–$150 (full DE grid set)
Closing with water above 65°FAlgae bloom under the cover by springAbout $100–$300 (chemical cleanup)

One more to remember in spring: never restart the pump with return valves closed or winter plugs still installed. The pressure spike can blow off filter lids, burst fittings, or burn out the mechanical seal. Prime the pump with water, open the air relief valve, and stand clear until a steady stream of water comes out.

Final Equipment Pad Checklist

Pool Pump Winterization Checklist
  • ☐ Power: Breakers off to the pump, heater, salt system, and automation.
  • ☐ Pressure: Filter air relief valve open; gauge reads 0 PSI.
  • ☐ Plumbing: Lines blown out with a blower under 5 PSI and plugged.
  • ☐ Pump drain plugs: Both removed (strainer pot and volute) and the housing fully drained.
  • ☐ O-rings: Cleaned, inspected, and coated with silicone or Teflon lube — no petroleum.
  • ☐ Plug storage: Drain plugs inside the pump strainer basket; lid on loosely.
  • ☐ Filter: Drained, media cleaned and stored indoors, bottom drain plug left out (unless your filter manual says to reinstall it).
  • ☐ Valves: Multiport or slide valve set to WINTER or between two positions.
  • ☐ Motor: Ventilated cover or indoor storage — no plastic wrap.
  • ☐ Antifreeze: Propylene glycol in the lines only, never in the equipment.

Through the winter, check the water level periodically and clear snow buildup of more than 12 inches from the cover. In spring, reinstall the drain plugs with fresh Teflon tape or silicone lube, re-lube the lid O-ring, and prime the pump before starting it.

ProTuff Telescopic Pool Pole

The pole for closing day and opening day
Telescopic Pool Pole

Skimming the pool clean before the cover goes on — and again when it comes off — is a lot easier with a pole that won’t bend or slip. The ProTuff telescopic pole is covered for life under the 490 Promise.

View Telescopic Pool Pole · $217.97

Frequently Asked Questions

How many drain plugs does an inground pool pump have?

Hayward, Pentair, and Jandy inground pumps each have two drain plugs: one at the base of the front strainer pot and a second farther back on the lower volute, or impeller housing. Remove both so the pump drains completely.

Where should I put the pump drain plugs over the winter?

Place the removed drain plugs inside the pump strainer basket and set the lid back on loosely. That keeps all the hardware together, so the plugs are right where you need them at spring startup.

Can I wrap my pool pump motor in plastic for winter?

No. Plastic wrap, trash bags, and airtight tarps trap condensation inside the motor, which rusts the stator and rotor and locks the bearings. Use a ventilated cover such as an upside-down tub with side cutouts, or store the pump indoors.

What lubricant should I use on pool pump O-rings?

Use a 100% silicone-based or Teflon-based pool lubricant such as Magic Lube, Boss 820, or Jack’s 327. Never use Vaseline, WD-40, or any petroleum product, because petroleum breaks down EPDM rubber O-rings and causes swelling, splitting, and air leaks.

Can I use automotive antifreeze in my pool plumbing?

No. Automotive antifreeze (ethylene glycol) is highly toxic and degrades plastic pool components. Use only non-toxic propylene glycol labeled for pool or RV use, at about 1 gallon per 10 feet of pipe, and never pour it into the pump, filter, heater, or chlorinator.

How much air pressure should I use to blow out my pool lines?

Stay below 5 PSI, using a low-pressure, high-volume pool line blower or a wet/dry shop vac. Hayward and Pentair warn against purging with compressed air, which can cause filter lids, tanks, and strainer covers to explode apart.

Should I store my pool pump indoors for the winter?

Indoor storage is the best option if your pump has quick-disconnect unions. Turn off power at the breaker, have the wiring disconnected, loosen the unions, and store the pump in a dry basement or garage away from pool chemicals, which can corrode the windings and bearings.

$1,000 Monthly “Freebie Friday” Drawing

You Could Win Free ProTuff Gear — Every Month

Pool Care GuideMaintenance Checklists45 Pool Games eBookWeekly Tips & Deals

No Spam. Unsub anytime. Remain subscribed, remain eligible every month.

Disclaimer: This guide is provided for informational purposes only and does not replace the manufacturer’s installation, operation, and maintenance documentation for your specific equipment. Pricing, specifications, and warranty terms vary across model years, firmware revisions, retailers, and regions — always reference the current manufacturer manual and confirm pricing with an authorized dealer for your area. Installation, electrical work, and ongoing service should be performed in accordance with federal, state, and local pool safety regulations. ProTuff Products assumes no liability for injuries, equipment damage, or warranty disputes resulting from the use of this information. When in doubt, contact a licensed pool service professional or the manufacturer directly.