Opens in a new tab
Backyard swimming pool and attached spa at dusk with a lit outdoor fireplace, patio seating, stone deck, waterfall edge, and plants.
Equipment Use

Gas Pool Heater Pressure Testing: What the Hayward, Pentair and Jandy Manuals Say

ProTuff Team

ProTuff Team
October 20, 2026 · Equipment Use

This guide covers gas pool heater pressure testing, model by model. Where a checked figure exists, it sits next to the model whose manual prints it. For anything else, check your heater’s nameplate and manual.

$1,000 Monthly “Freebie Friday” Drawing

You Could Win Free ProTuff Gear — Every Month

Pool Care GuideMaintenance Checklists45 Pool Games eBookWeekly Tips & Deals

No Spam. Unsub anytime. Remain subscribed, remain eligible every month.

Two Different Pressure Tests on a Gas Heater

“Pressure testing” can mean the gas side of a pool heater or its water pressure switch. Each is covered below, and each is set out in your heater’s installation manual.

A third event touches the heater without being a heater test at all: a plumber or gas fitter pressure-testing the gas supply piping. The manuals have specific rules for protecting the heater when that happens.

Protecting the Heater During a Gas Line Test

When new gas piping is installed or repaired, it is usually pressure-tested before use. A gas valve is built for low pressure, so a heater left connected during a high-pressure line test can be damaged.

For the Pentair ETi 250, the manual says the heater and its individual shut-off valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psig, which means you disconnect the heater and its individual shut-off valve.

At test pressures equal to or less than 1/2 psig, the Pentair ETi 250 manual says to isolate the heater instead: close the individual manual shut-off valve.

⚠ Reconnecting After the Test

Before the heater is reconnected after a gas line test, read the gas pressure testing caution in your heater’s manual.

Hayward and Jandy manuals also carry a gas line testing rule. The test pressure that decides between disconnecting and isolating the heater is printed in each heater’s installation manual, so check your own heater’s manual before the gas line is tested.

Inlet vs. Manifold Pressure: What Each Manual Measures

Your heater’s manual names the point for each gas pressure reading and the range that goes with it. The models below are the ones with checked figures.

HAYWARD
UHS manual

  • UHS: On Hayward UHS heaters, the manifold pressure reading with the heater running should fall at 1.8-2.0 in. WC (natural, manifold pressure reading with the heater running); inside that range, no further adjustment is needed.
  • UHS: On Hayward UHS heaters burning propane, the manifold pressure reading with the heater running should fall at 6.8-7.0 in. WC (propane, manifold pressure reading with the heater running); inside that range, no further adjustment is needed.
  • HDF: The HDF owner’s manual prints its required inlet and manifold gas pressures in a table. Take the figures from your heater’s manual.
  • Other heaters on the line: Hayward’s UHS procedure also covers what to do when more than one pool or spa heater shares the same gas supply line. Read that step in your manual before you take the reading.
PENTAIR
ETi 400 kit guide

  • ETi 400: In the Pentair ETi 400 gas valve kit guide, after the burner lights, verify that the supply pressure is within 4-12 in. WC (supply pressure, after the burner lights).
  • Other Pentair models: MasterTemp, Max-E-Therm and ETi 250 heaters use their own procedures and ranges. Check the nameplate and the installation manual for your exact heater.
JANDY
JXi manual

  • JXi: Check the JXi manual for the conditions the inlet reading must be taken under.
  • JXi: The JXi manual’s Table 3 limits are shown in the table below.
Jandy model and gasMAX inlet gas pressure (in. W.C., all readings made while heater is operating)MIN inlet gas pressure (in. W.C., all readings made while heater is operating)
JXi, natural gas10.54
JXi, liquid propane144

When the Gas Pressure Drops After the Burner Lights

If the supply pressure on a Pentair ETi 400 falls below its range once the burner lights, check what the gas valve kit guide says about the gas line.

If a Jandy JXi’s gas supply pressure is less than required, the JXi manual lists what to check between the meter and the heater.

🚫 Low Supply Pressure

Have a qualified gas fitter or your gas utility check the gas supply, and follow your heater’s manual for any adjustment at the valve.

The Water Pressure Switch and Heater Height

The manuals below give water pressure switch limits based on where the heater sits compared with the pool.

PENTAIR
MasterTemp and ETi 400 manuals

  • MasterTemp: On the Pentair MasterTemp, the water pressure switch is set at 3.00 PSI (factory setting, heater installed at pool level), plus or minus 0.75 PSI (plus or minus tolerance on the factory setting).
  • MasterTemp: If a Pentair MasterTemp is installed more than 1 ft above or below pool level, the manual says the switch must be adjusted by a qualified service technician.
  • MasterTemp: If a Pentair MasterTemp is installed more than 5 ft above the pool or more than 4 ft below the pool level, the manual says it is beyond the limits of the pressure switch and a flow switch must be installed.
  • ETi 400: On the Pentair ETi 400, if the water pressure switch is installed more than 3 ft above the pool or more than 3 ft below the pool level, the manual says a flow switch must be installed.
JANDY
JXi manual

  • JXi: The Jandy JXi factory-installed water pressure switch can accommodate elevations of 6 ft above the pool water surface or 11 ft below the pool water surface.
  • JXi: If the heater’s water connections sit outside that range, the JXi manual says to consult your local Zodiac representative for recommendations.
HAYWARD
Check your heater’s manual

  • UHS and HDF: Hayward’s manuals describe their own switch adjustment for heaters above or below the water level. Use the procedure and settings in your heater’s manual.
⚠ A Safety Switch, Not a Nuisance

The water pressure switch is a safety device. Never jumper it or bypass it to get a heater running. If it will not close with the pump on, check your heater’s manual and call a qualified technician.

Who Should Do the Testing

Gas pressure testing is skilled work with real stakes: Pentair’s ETi 250 manual warns that over-pressurized gas valves are not covered by warranty. In practice, that means:

Before anyone tests gas pressure on your heater
  • ☐ Find the manual: Match the model on the heater’s rating plate to its installation manual.
  • ☐ Confirm the gas type: Check the rating plate for natural gas or propane.
  • ☐ Know the measuring point: Inlet and manifold readings are not interchangeable.
  • ☐ Protect the valve: Check your heater’s manual before the gas line is pressure-tested.
  • ☐ Call a pro: Use a qualified heater technician or licensed gas fitter for the test and any adjustment.

Frequently Asked Questions

Can I check my pool heater’s gas pressure myself?

A homeowner can find the model and gas type on the rating plate and keep the manual ready for the technician. The test itself, and any adjustment, is a job for a qualified heater technician or gas fitter working from your heater’s manual.

Why does my heater light and then shut off?

There are several possible causes, on the gas side and the water side, and they differ by model. Check the troubleshooting section of your heater’s manual, or call a qualified technician to find the cause.

Do I need a flow switch instead of a pressure switch?

It depends on how far above or below the pool your heater sits, and each model has its own limit. Pentair’s MasterTemp and ETi 400 manuals and Jandy’s JXi manual each give a height range, shown in the water pressure switch section above. Outside it, follow your manual’s instructions.

$1,000 Monthly “Freebie Friday” Drawing

You Could Win Free ProTuff Gear — Every Month

Pool Care GuideMaintenance Checklists45 Pool Games eBookWeekly Tips & Deals

No Spam. Unsub anytime. Remain subscribed, remain eligible every month.

Disclaimer: This guide is provided for informational purposes only and does not replace the manufacturer’s installation, operation, and maintenance documentation for your specific equipment. Pricing, specifications, and warranty terms vary across model years, firmware revisions, retailers, and regions — always reference the current manufacturer manual and confirm pricing with an authorized dealer for your area. Installation, electrical work, and ongoing service should be performed in accordance with federal, state, and local pool safety regulations. ProTuff Products assumes no liability for injuries, equipment damage, or warranty disputes resulting from the use of this information. When in doubt, contact a licensed pool service professional or the manufacturer directly.