An automatic cover changes your pool’s chlorine demand the moment it closes. Sunlight stops burning chlorine off, and debris stops landing in the water. The Hayward AquaRite S3 manual puts it simply: “When the pool cover is closed, chlorine is not lost to sunlight and bacteria load is typically reduced, requiring less chlorine.”

A salt chlorine generator that keeps running at its open-pool setting under a closed cover keeps adding chlorine the water no longer needs. An auto cover chlorinator interlock fixes that. A switch on the cover tells the automation or the chlorinator that the cover is closed, and the system cuts chlorine to a lower setting you choose. This guide walks through how Hayward, Pentair and Jandy each do it, using their own manuals.

$1,000 Monthly “Freebie Friday” Drawing

You Could Win Free ProTuff Gear — Every Month

Pool Care GuideMaintenance Checklists45 Pool Games eBookWeekly Tips & Deals

No Spam. Unsub anytime. Remain subscribed, remain eligible every month.

How a Cover Interlock Works

Every interlock in this guide uses the same basic idea. The cover mechanism has a position switch. That switch is wired as a low-voltage input to either the automation controller or the chlorinator’s own power center. When the input says “cover closed,” the controller swaps to a second set of settings.

Which settings change depends on the system:

  • Chlorine output: lowered or capped to a cover-closed level you set.
  • Pump speed or run time: reduced on systems that support it.
  • Water features, spillover and lights: switched off so water does not spill onto or pile up on the cover.

When the cover opens again, the controller returns to your normal settings. You set the cover-closed values once, during setup.

Key Takeaway

The interlock does not pick a chlorine level for you. You set the cover-closed output during setup, and the allowed range differs by system. Check your controller or chlorinator manual for the range on your exact model.

Hayward: OmniLogic, OmniPL and AquaRite S3

Hayward handles the cover in two places, depending on what runs your pad.

OmniLogic and OmniPL: the Pool Cover Interlock

On OmniLogic and OmniPL, you turn the feature on in the Configuration Wizard under Interlocks. The Hayward automation manual describes it this way: “This interlock makes it easy to assign specific pool settings when the cover is closed. Pump speed, heater temperature and chlorination percentage can all be preset for periods when the pool cover sensor (external input) detects that the cover is closed.”

A second interlock covers spillover. The manual says interlocking Spillover to the pool cover sensor means “water cannot spill into the pool when the cover is in the closed position.” This needs the cover sensor already set up as an external input.

AquaRite S3: direct cover input

The AquaRite S3 can read the cover itself, without a separate automation system. Per its manual, it “can automatically scale back operational limits (both chlorination setpoint and pump speed) to ensure overchlorination doesn’t occur.”

The AquaRite S3 pool cover sensor must use a normally open switch wired to the pool cover terminals. On the controller, the Pool Cover menu lets you enable or disable cover detection, set a pump speed, and set a Chlorination value. That value is a ceiling: the manual says that when the cover is detected, the unit “will produce up to, but no more than this setting.” The setting range is listed in the Pool Cover menu section of the AquaRite S3 owner’s manual.

When the cover is closed, the AquaRite S3 display reports that the external pool cover sensor is active. The manual notes this sensor is wired to the SENS3 COVER terminal.

💡 Pro Tip

If the AquaRite S3 never shows the cover sensor as active when the cover is shut, confirm that cover detection is enabled in the Pool Cover menu before you suspect the switch.

Pentair: IntelliCenter and iChlor SmartSense

IntelliCenter with the Pool Cover Expansion Card

IntelliCenter reads the cover through the Pool Cover Expansion Card (P/N 522039Z). Per Pentair’s install guide, the card goes into an expansion slot on the main control board and gives inputs for up to two covers (Pool Cover 1 and Pool Cover 2).

Setup is done from the IntelliCenter screen. The guide’s path is Settings › Advanced System › Configurations › Installation Setup › Pool/Spa Cover. From there:

1
Cover Enabled

Select Enable, then select Pool Cover 1.

2
Cover State Normally

Pick the state the cover is usually in. The guide notes the pool cover controller is set up as a normally open configuration and says to select Open.

3
Affected Circuits

Select Configure, then choose the circuits you want switched off or on when the cover is closed or open.

4
IntelliChlor Active

Select ON to switch the IntelliChlor SCG circuit off when the cover is closed.

5
IntelliChlor Output

Set the IntelliChlor output to use while the cover is closed. The allowed range is printed in the IntelliCenter Pool Cover Expansion Card installation guide; check it there before you choose a value.

iChlor with SmartSense Cover Detection

The iChlor can react to a cover on its own. Pentair calls this SmartSense Cover Detection. The iChlor manual says it lets “iChlor cells receive a ‘pool cover’ signal and reduce the chlorine output when the cover is closed.” The cover-closed signal is a dry contact input to the power center board.

The iChlor remembers the cover-closed output you set and reuses it every time the cover closes. The manual also caps how high that output can go while the cover is closed. For the default level and the cap on your unit, see the SmartSense Cover Detection section of the iChlor installation and user’s guide.

ℹ iChlor needs the PC100 Power Center

The iChlor manual says pool cover detection is only available when the iChlor is installed alongside a PC100 Power Center (P/N 520556). It also labels the feature “stand-alone mode only.”

Jandy: AquaLink RS with the Cover-Pools Interface

Jandy’s route is the Cover-Pools/AquaLink RS Interface board (model H0370100). It links an AquaLink RS system to a Cover-Pools Auto-Shutoff Controller. Per its manual, it is for use with AquaLink RS OneTouch systems with Rev R firmware or later. The cable to the cover controller lands on the board’s 4-pin J5 connector.

Jandy describes what you get: when the cover is closed, AquaLink “can automatically deactivate any lights and water features, limit chlorine output and reduce pump run time.”

Two menus under MENU › SYSTEM SETUP › COVER-POOLS do the work:

  • Disable Devices: pick the auxiliary devices, such as water features, a booster pump cleaner or lights, that switch off when the cover closes.
  • AquaPure Adjust: set a separate SET POOL and SET SPA chlorine percentage that applies only while the cover is closed. Highlight the line, press SELECT, change the value with the arrow keys, and press SELECT again.

The Jandy manual does not tell you which percentage to pick. Check your chlorine level with the cover closed and adjust from there.

Safety Warnings You Must Not Skip

A cover interlock is a convenience feature. The manuals are clear that mistakes around covers can be deadly, so read these before you wire or program anything.

🚫 Jandy: reversed cover sensors are a drowning hazard

Jandy warns that if the Cover-Pools/AquaLink RS Interface motor directions, key switch or magnet are wired wrong, the sensors may read closed when the cover is open, which is a drowning hazard; the fix is to exchange the purple and brown wires on the J5 connector.

🚫 Pentair: EasyTouch and IntelliTouch must not control a cover

Pentair warns not to use an EasyTouch or IntelliTouch system to control an automatic pool cover, because swimmers can become entrapped under the cover.

⚠ Hire the right person

The Jandy Cover-Pools interface manual says the product must be installed and serviced by a contractor who is licensed and qualified in pool equipment. If you are not sure who should do the wiring on your system, check your model’s manual and use a licensed pro.

Side-by-Side Comparison

SystemCover input hardwareWhat can change when the cover closesWhere you set it
Hayward OmniLogic / OmniPLPool cover sensor set up as an external inputPump speed, heater temperature, chlorination percentage; spillover blockedConfiguration Wizard › Interlocks
Hayward AquaRite S3Normally open switch on the pool cover terminalsChlorination ceiling and pump speedPool Cover menu
Pentair IntelliCenterPool Cover Expansion Card (P/N 522039Z)Chosen circuits off/on; IntelliChlor circuit off or set to a cover-closed outputInstallation Setup › Pool/Spa Cover
Pentair iChlorDry contact input to the PC100 Power Center boardChlorine output reduced to your saved cover-closed settingiChlor SmartSense Cover Detection
Jandy AquaLink RSCover-Pools/AquaLink RS Interface (H0370100)Chosen devices off; separate pool and spa chlorine settingSystem Setup › Cover-Pools

Frequently Asked Questions

Do I need full automation to use a cover interlock?

Not always. The Hayward AquaRite S3 reads a cover switch directly, and the Pentair iChlor reads one through its PC100 Power Center. On IntelliCenter and AquaLink RS, the interlock runs through an add-on card or interface board.

Can I still turn the water features on while the cover is closed?

The interlocks are built to stop that. Hayward’s spillover interlock blocks spillover when the cover sensor reads closed, and Jandy’s Disable Devices list and IntelliCenter’s Affected Circuits switch off the features you pick.

What should I check if the system acts like the cover is open when it is closed?

First confirm cover detection is enabled in your controller’s cover menu. On the Jandy Cover-Pools interface, a reversed reading points to the wiring problem covered in the safety section, so have a qualified pro correct it before you rely on the cover.

How low should I set chlorine output when the cover is closed?

None of these manuals hands you one number for every pool. Start from the range your controller’s manual allows, test your free chlorine after a few days with the cover closed, and adjust.

$1,000 Monthly “Freebie Friday” Drawing

You Could Win Free ProTuff Gear — Every Month

Pool Care GuideMaintenance Checklists45 Pool Games eBookWeekly Tips & Deals

No Spam. Unsub anytime. Remain subscribed, remain eligible every month.

Disclaimer: This guide is provided for informational purposes only and does not replace the manufacturer’s installation, operation, and maintenance documentation for your specific equipment. Pricing, specifications, and warranty terms vary across model years, firmware revisions, retailers, and regions — always reference the current manufacturer manual and confirm pricing with an authorized dealer for your area. Installation, electrical work, and ongoing service should be performed in accordance with federal, state, and local pool safety regulations. ProTuff Products assumes no liability for injuries, equipment damage, or warranty disputes resulting from the use of this information. When in doubt, contact a licensed pool service professional or the manufacturer directly.